![Microcanner MC202 Operating Instructions Manual Download Page 11](http://html1.mh-extra.com/html/microcanner/mc202/mc202_operating-instructions-manual_1785649011.webp)
microcanner MC202
MC202 OIM (V1.0)
Page
11 of 30
6.
Plug in the machine power, hook up the air supply, connect Co2 at filer head,
attach cold water supply, and attach supply of sanitizer to the filling station.
7.
With the machine on, e-stop button off, and the fill station raised, put the machine
into paused mode. On the fill station screen (7.4) on the HMI hit the on/off button
to open the valves and let the sanitizer flow completely through the fill lines.
a.
During this process leave 6 cans under the filling station so they will fill
with sanitizer.
b.
Make sure sanitizer has fully made it through the system.
c.
Using the fill station screen, lower the fill station so that the fill tubes and
float switches can be soaked with sanitizer.
d.
On the HMI turn the fill valves off.
e.
Let sit for desired amount of time.
f.
Raise the fill station.
g.
Remove the 6 cans filled with sanitizer.
h.
Fully purge system with product.
8.
Hook up water supply to rinse station(s). Turn on water supply
9.
Load ends into cap feeder station.
10.
Turn machine to automatic mode.