Disclaimer

Welcome you to purchase our MMW radar product which is designed and
produced by Changsha Microbrain Intelligent Technology Co., LTD. You can
get more details at our official websit:Microbrain Intelligent Technology Co.,
LTD. Official website http://www.microbrain.com.cn.
Please read this statement CAREFULLY before opening the package and
powering on the radar. Once open, it will be deemed to be an approval and
acceptance of the contents of this statement. Please mount and use the
product in strict accordance with the instructions list in this manual. Changsha
Microbrain Intelligent Technology Co., Ltd. will not be responsible for any loss
or compensation due to the damage or cost caused by improper mount or
usage.
All rights Reserved to Changsha Microbrain Intelligent Technology Co., LTD.
Reproduction, Copy, or Revision in any form without permission of Changsha
Microbrain Intelligent Technology is illigal and will be charged. The use of the
products and manuals will not be subject to patent liability.

Summary of Contents for IML-D01

Page 1: ...User Manual of IML D01 Millimeter Wave Radar for Vital Signs Monitoring Microbrain Intelligent Technology Co Ltd...

Page 2: ...pproval and acceptance of the contents of this statement Please mount and use the product in strict accordance with the instructions list in this manual Changsha Microbrain Intelligent Technology Co L...

Page 3: ...CATALOG 1 Introudution 1 2 Product features 2 3 Product parameters 3 4 Delivery list 4 5 Mount and debug 4 6 Quick use steps 6 7 Precautions for product use 10 8 Frequently asked questions FAQ 10...

Page 4: ...s and processing the scattered signal by human chest IML D01 radar is capable of extracting the heart rate respiration rate and other position information of a human from their doppler modulation sign...

Page 5: ...2 2 Product Features Type Health care Model IML D01 Dimensions 72 72 19 7mm Weight Less than 70g FIG1 IML D01 Apperance...

Page 6: ...ge Resolution cm 3 3 Stable heart rate build time s 25 6 Stable respiration rate build time s 12 8 Back to monitor Monitoring Range m 0 1 0 7 Range Resolution cm 3 3 Stable heart rate build time s 16...

Page 7: ...the gray radome facing outwards the normal of the radome surface could be viewed as the illumination line as shown in Figure 3 And the customer should make sure that the illumination line shoud be pa...

Page 8: ...5 FIG 3 Mounting demonstration of IML D01 front detection Figure4 Mounting demonstration of IML D01 back detection...

Page 9: ...result could be directly displayed on the GUI of the software The use of this tool is conducive to the use of IML D01 sensor The test steps are as list as follows Step1 Preparation of relative testing...

Page 10: ...ay Switch Signal Green Reserved Maximum voltage of full load 60VDC VAC Maximum current of full load 600mA 6 Relay Switch Signal White Reserved Table 3 Definition of Radar Pins Note Please consult the...

Page 11: ...8 FIG 5 Gui of the debug Software in the host computer FIG 6 Demo run of the debug Software in the host computer...

Page 12: ...ebug Do not try to disassemble or repair by yourself Any problems encountered in the using please contact to the customer service of Changsha MicroBrain Intelligent Technology Co LTD 8 Frequently aske...

Page 13: ...of different persons 4 The heart rate veries fast A The heart rate may vary a lot during the test which dues to the fact that the heart rate may change with the environmental noise interference from o...