background image

                                                                                                                                                     broch15f.doc

 

1

 
 
 
 
 

OPERATOR’S MANUAL 

MODEL VM10C 

 
 
 
 
 
 
 
 
 
Micro Seven, Inc. 
1095-K N.E. 25

th

 Hillsboro, OR 97124 U.S.A. 

 
phone: 503-693-6982 
fax: 503-693-9742 

[email protected]

 

www.microseveninc.com

 

 
Copyright, 

2013 by Micro Seven, Inc. All right reserved. 

Contents of this publication may not be reproduced in any form without the written 
permission of Micro Seven, Inc. 
 
All requests for repairs should be directed to the factory. 
 
This instrument is warranted against defective workmanship and materials for a period 
of six months. There will be no warranty when the instrument is misused, or when the 
factory seal on the instrument is broken. 
 
Printed in U.S.A. 
 
Specification and price change privileges are reserved. 

Summary of Contents for VM10C

Page 1: ...s of this publication may not be reproduced in any form without the written permission of Micro Seven Inc All requests for repairs should be directed to the factory This instrument is warranted against defective workmanship and materials for a period of six months There will be no warranty when the instrument is misused or when the factory seal on the instrument is broken Printed in U S A Specific...

Page 2: ...area Each voice segment for numerical and legend voice element is programmable via a built in microphone by using control software and the recorded voice may be saved at a file in a computer or downloaded into VM10 C The PC interface enables PC controlled measurement of DC and AC voltage and resistance Original MICRO SEVEN Model VM10 HAND HELD Voiced Multi meter is shown in above picture VM10 C do...

Page 3: ...ously will place VM10 Cinto mode programming SW 3 Start button for manual push button for starting voiced measurement Power indicator SW4 Power switch J1 and J2 Input terminals for volt DC volt AC resistance J3 not used Rear panel description 12VDC input connector from 117V AC DC adapter D sub9 for RS232 interface Numerical voice data 0 5 seconds 0 1 2 3 4 5 6 7 8 9 decimal point over range indica...

Page 4: ...ty if any factory seal is broken Service is performed at the factory usually within 5 working days Optional features 1 Internal rechargeable battery 2 International AC DC power adapter for 90 250VACRMS and 50 60Hz power input 3 Car battery adapter 4 USB RS232 adapter 1 Battery option with Ni Cad battery pack Power 2 5 hours of battery operation Recharging time 24 hours Charge discharge cycles 100 ...

Page 5: ...ial Make a VM10 directory in your PC and copy all files in the disk or CD that is supplied into the directory Find out RS232 communication port number in device manager in the control panel of Windows If it is other than com1 use a text editor to edit to change from COM1 in a file commport to your assigned communication port number If USB RS232 option is required to interface USB in your PC to RS2...

Page 6: ...Mode inquiry to find mode setting Q93 Data output 00 for volt DC 01 for volt RMS or 02 for resistance Range register programming M940n where n is 0 for the lowest range like 200mVDC or 2k ohm Range inquiry to find range setting Q94 Data output 00 for 200mVDC 01 for 2VDC in volt DC mode Sound volume MBD n1 n2 Continuous mode rate MAB n1 n2 where n1 and n2 forms a hexadecimal number Multiply two sec...

Reviews: