PAGE 16
© 2016 OJ Electronics A/S
PLI : Power Limit 2/2
Equation to calculate number of minutes that could be
entered in the PLI menu - when an average heating effect
is desired:
Average desired heating effect per m
2
Floor heating element effect per m
2
(
1-
(
)
)
∗
60 min .
Note!
If the result of the equation is negative, then nothing
should be entered .
The function is factory-set to 0 minutes but can be set to
values between 0-30 minutes in increments of 1 minute .
How to execute it:
• Access the menu .
• Scroll through the menu to PLi .
• Press the centre button to enter the Power limit
settings .
• Use the upper or lower button to set the number
of minutes by which you want the heating to be
deactivated per hour .
• Confirm your choice with the centre button .
Menu structure:
PLi: 0-30
Factory: 0