Technical Data
Model
DZ140 (Controller)
Sensors
DS05(03) DS05(04) DS05(07) DS05(14) DS05(15)
DS1
DS1(04)
DS1/T
Measuring principle /
Target (blade material)
eddy current principle / aluminum or titanium
Maximum speed range
(measuring range)
200 ... 400,000 RPM
Operating
temperature
Controller
-40 ... +125 °C, -40 ... +257 °F (at a maximum of 15 VDC supply voltage)
1)
Sensor
-40 ... +200 °C,
-40 ... +392 °F
-40 ... +235 °C,
-40 ... +455 °F
-40 ... +235 °C,
-40 ... +455 °F
(short-term
+285 °C, +545 °F)
Sensor cable
-40 ... +200 °C, -40 ... +392 °F
Integral sensor cable
0.5 m ±0.15 m
0.75 m ±0.15 m
0.8 m ±0.15 m
Number of blades
rotary switch (accessible from the outside) for 1 up to 16 blades
Digital output
1 pulse / blade (switch
Blades
on 1, TTL level, variable pulse duration) or
1 pulse / revolution (switch
Blades
on 2...16, TTL level with 100 µs pulse duration)
Analog output
Mode 1, 3, 5: 0 ... 5 V (200 ... 200,000 rpm)
Mode 0, 2, 4: 0 ... 5 V (200 ... 400,000 rpm)
mode rotary switch, adjustable, accessible from outside
RAW signal
Analog measurement signal to control distance between sensor and blade by means of an oscilloscope,
load resistance > 5 kOhm, load capacity max. 1 nF
Output sensor temperature
0 ... 5 V (-50 ... +300 °C, -58 ... +572 °F)
Power supply
9 V ... 30 VDC / max. 50 mA (short-term up to 36 VDC)