Page 57
Instructions for Operation
Top-Line Video Endoscope
7.4
Image not Bright Enough
Light source intensity is at a low setting.
Turn to maximum intensity.
Probe tip may be too far from object.
Move probe tip closer to object.
If using a detachable tip adapter, the probe tip may
not be properly attached.
Detach tip adapter and reinstall.
The lenses or glass windows may be dirty.
Clean glass surfaces on probe tip, light guide
connector and the eyepiece with alcohol and
cotton swabs (or soft cloth), see Chap.
.
Also clean detachable tips if being used, see
Light source capacity may be insufficient for ap-
plication.
8.
Instructions for Operation
8.1
SD Memory Card
Do not remove the SD memory card during image and video capture. This can cause data loss and damage
to memory card.
i
We recommend a 80x SD card for best video quality, see Chap.
8.2
Cleaning
Use cotton swabs and lens cleaning fluid or isopropanol (rubbing alcohol) for cleaning the optics.
Clean the display with a clamp cloth only.
i
Do not use chemical solvents, commercial glass cleaner or other cleansing agents.