surfaceCONTROL 3D 35xx

7. 

LED Displays

LED LED

Meaning

Fig. 9 LED displays

Off

LED not active

Constant green

LED active

LED State

Meaning

Flashing orange

Initialization of sensor hardware

Flashing green

Initialization of communications interface

Constant green

Sensor is ready for operation

Flashing  
orange-green

Error during initialization of sensor hardware 
Communication with sensor possible

Constant red

Error during initialization 
No communication with sensor possible

LED Power

Meaning

Off

No operating voltage or operating voltage 
too low

Constant green

Operating voltage applied

Constant red

Error, operating voltage too high

LED Data  
(Link / Act)

Meaning

Link LED (left): 
Constant orange Gigabit Ethernet connection established
Constant green

100 Mbit Ethernet connection established

Off

10 Mbit Ethernet connection established

Act LED (right):
Green

Active data transmission

Off

No data transmission

LED I/O

Meaning

reserved

Summary of Contents for surfaceCONTROL 3D 35 Series

Page 1: ...ly be opened by authorized persons Damage to or destruction of the sensor Do not touch the protective windows of the optics Wipe off any fingerprints immediately with pure alcohol and a clean cotton c...

Page 2: ...Ambient pressure Atmospheric pressure 1 Max permissible operating temperature depends on installation scenario thermal connection and operating mode If necessary external heat dissipation must be use...

Page 3: ...included in risk group 2 according to EN 62471 2008 Do not look into the lens Consciously close your eyes or immedi ately turn away if the optical radiation enters the eye The warning sign below is at...

Page 4: ...to 2 A per pin Designation Pin no Cable color ECR3000 x Notes Connection view U B 1 Brown 18 V 30 V DC rated value 24 V 1 2 4 3 View Plug on housing side U B 2 White GND 3 Blue 0 V GND 4 Black Screen...

Page 5: ...White reserved 1 Brown reserved 12 Red blue reserved 11 Gray pink reserved 10 Purple GPIO1 4 Green General purpose IO 1 hardware trigger GPIO2 6 Yellow General purpose IO 2 GPIO3 8 Gray General purpos...

Page 6: ...ger to start a measurement and is directly connected to the sequence control in the sensor The functionality of the digital signals can be programmed see Fig 5 In addition to direction polarity can al...

Page 7: ...sensor is active start at exposure of first image end at completion of data transmission via GigE ExposureActive Image sequence recording is enabled for current frame start at first image end at last...

Page 8: ...RV Customer Device Sensor All inputs can be used as logical inputs but not for time critical tasks Electrical Parameters of Digital Outputs Multi Function Connection The digital outputs require an ext...

Page 9: ...Communication with sensor possible Constant red Error during initialization No communication with sensor possible LED Power Meaning Off No operating voltage or operating voltage too low Constant gree...

Page 10: ...itializa tion After completion it is constantly illuminated green For more information see the LED Displays section see Chap 7 i The surfaceCONTROL 3D 35xx sensor requires a warm up time of typically...

Page 11: ...y surfaces reflections from the test object can be reduced by inclining the sensor by up to 30 with respect to the surface of the test object Alignment with Crosshair You will achieve the best results...

Page 12: ...aused by improper handling the use of force or by repairs or modifications by third parties is not covered by the liability for material defects Repairs are carried out exclu sively by MICRO EPSILON F...

Reviews: