MICRO-EPSILON
X9751109-B060097MSC
19
Mounting
5.2
Attachment and Mounting of the Controller
The controller can be mounted using four M4 DIN 84 screws instead of the rubber feet,
see dimensional drawings in the annex. To do this, the corner protection caps should
be pulled off carefully to the side (e.g. with a screwdriver) and plugged on again after
mounting. The controller should be mounted such that the function-indicating LEDs are
not hidden. When mounting the controller particular care is needed in the routing of the
cables and their strain relief.
Fig. 5.5: Dimensional
drawing controller
scanCONTROL28x0
laser off
on
1394
1394
1394
RS 232
RS 422
video
analog
laser on
power on
error
sensor
control
mode
mode 2
mode 1
3
reset
24VDC
synchron
246 (9.69)
105.5 (4.15)
107 (4.21)
278 (10.9)
178 (7.01)
186.8 (7.35)
146 (5.75)
4 rubber feet for mounting
holes dia. 6.0 mm