background image

Page 1

scanCONTROL 2910/2960BL

Assembly Instructions

scan

CONTROL

 

2910/2960BL

1. 

Warnings

Connect the power supply and the display-/output device according to the safety 
regulations for electrical equipment. The supply voltage must not exceed the specified 
limits.

 

> Risk of injury, damage to or destruction of the sensor

Avoid shocks and impacts to the sensor. Avoid constant exposure of the sensor to dust 
and splashes of water. Avoid exposure of sensor to aggressive materials (detergents, 
cooling emulsions).

 

> Damage to or destruction of the sensor

Read the detailed operation instructions before operating the sensor.  
These instructions are available Online at 

www.micro-epsilon.com

.

2. 

Notes on CE Marking

The following apply to the scanCONTROL 2910/2960-xx/BL:  

 - EU Directive 2014/30/EU
 - EU Directive 2011/65/EU

The sensor is designed for use in industrial environments. 
The sensor satisfies the requirements if the guidelines in the operation instructions are 
maintained in installation and operation.

3. 

Proper Environment

 - Protection class: 

IP65

 - Temperature range:

 

ƒ

Operation: 

0 ... +45 °C (+32 ... +113 °F), for free circulation of air

 

ƒ

Storage: 

-20 ... +70 °C (-4 ... +158 °F)

 - Humidity: 

5 - 95 % (non-condensing)

Summary of Contents for scanCONTROL 2910

Page 1: ...ents cooling emulsions Damage to or destruction of the sensor Read the detailed operation instructions before operating the sensor These instructions are available Online at www micro epsilon com 2 Notes on CE Marking The following apply to the scanCONTROL 2910 2960 xx BL EU Directive 2014 30 EU EU Directive 2011 65 EU The sensor is designed for use in industrial environments The sensor satisfies ...

Page 2: ...d the versions valid for the user s country must be attached before the device is put into operation for the first time i If both warning labels are covered over when the unit is installed the user must ensure that supplementary labels are applied Laser radiation Close your eyes or immediately turn away if the laser beam hits the eye Irritation or injury of the eyes possible Laser Class 2M The sen...

Page 3: ...s 5 Unpacking Included in Delivery 1 scanCONTROL 2910 2960 xx BL sensor with integrated controller 1 PCR3000 5 multifunction cable length 5 m for power supply trigger and RS422 screw connector and free cable ends Calibration protocol assembly instructions 2 Protective caps ...

Page 4: ...witching input In3 GND In3 7 Black Ground connection In3 Shield Housing Black Not electrically connected to GND 2 3 4 5 6 7 8 9 1 10 11 12 GND galvanically isolated from IN1 IN2 IN3 RS422 laser on off laser on off input galvanically isolated from GND IN1 IN2 IN3 RS422 IN1 IN2 IN3 RS422 inputs galvanically isolated from GND and laser on off 12 pin screw connector view on solder side cable RS422 Syn...

Page 5: ... V HLL level Low 0 V 3 V high 11 V 24 V permitted to 30 V internal pull up 10 kΩ connected to 24 V Pulse duration 5 µs External Laser Switch off Optional The external laser switch off is implemented as a hardware solution and has a top prior ity The laser can be switched off in addition also by software This function is offered by sensors with the BL SI option Use a serial key switch in the contro...

Page 6: ...ddress in the link local net 169 254 x x No collision check is performed This is also the standard setting The sensor supports DHCP This setting is activated by default and has priority over the retrieval in the link local net The sensor scanCONTROL 2610 2960BL supports Power over Ethernet If the sensor is connected to a POE capable network adapter switch and you also use the power supply of the m...

Page 7: ...ws 10 each 32 bit and 64 bit 1 GHz or faster 32 bit and 64 bit processor 1 GB RAM Screen resolution 1024x768 scanCONTROL 3D View The following minimum system requirements are necessary Windows 8 or 8 1 64 bit Windows 10 64 bit 1 GHz or faster 64 bit processor 1 GB RAM Screen resolution 1024x768 Graphic card GPU with OpenGL 3 1 or higher 8 Transmitting Measurement Results scanCONTROL 2910 2960BL of...

Page 8: ...ly Close connection plugs you do not require with the includ ed protective caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds Now you can operate the scanCONTROL measuring system with the scanCONTROL software packages i Operating the sensors via Ethernet may require the IP settings of the PC sensor or the fire...

Page 9: ...ween scanCONTROL and PC On the left side you can adjust the settings for your measurement task The right side shows the profile data and further information about the measurement 11 How to Access Profile Data Profile data of scanCONTROL can be accessed via GigEVision and GenICam for digital cameras via Ethernet SDK for fast application integration C C C and others Please refer to the respective SD...

Page 10: ... filter module 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler A1 A2 13 14 750 536 A3 A4 A5 A6 A7 A8 Digital outpu DO 1 Status DO 7 DO 7 DO 1 DO 5 DO 3 L1 L2 L3 N PE OU Filter module OU Fieldbus coupler 13 14 C D B A 750 626 Ñ 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON ...

Page 11: ...ply in contacts of the fieldbus coupler 0 V and 24 V Connect the system supply in of the OU Filter module to the power supply 0 V and 24 V Connect the field supply in of the OU Filter module to the power supply 0 V and 24 V or 0 V and 5 V i The system supply and field supply should be separated to ensure bus operation and electrical isolation if an actor short circuits 14 Additional Information Pl...

Page 12: ...valuation carried out of a scanCON TROL SMART sensor can be transmitted to a PLC via one of these fieldbus systems Furthermore all scanCONTROL sensor settings can be set via the scanCONTROL Gateway e g Laser on off or switch User Mode Sensor parameterization Power supply Triggering Encoder Synchronization Mode switching Sensor control Gateway parameterization USB Ethernet Switch scanCONTROL Gatewa...

Reviews: