scanCONTROL 25xx

11. 

2D/3D Gateway

2D/3D Gateway allows for scanCONTROL SMART sensors to be integrated into various 
fieldbus systems:

 - PROFINET
 - EtherNet/IP
 - EtherCAT

All measurement results obtained from the profile evaluation performed by a  
scanCONTROL SMART sensor can be transmitted to a PLC via one of these fieldbus 
systems. Furthermore, all scanCONTROL sensor settings can be set via the 2D/3D 
Gateway (e. g. Laser on/off or User Mode).

Sensor 
parameterization 

Supply voltage
Triggering
Encoder
Synchronization
Mode switching
Sensor control

Gateway parameterization

USB

Ethernet
switch

2D/3D Gateway

The 2D/3D Gateway can connect up to four scanCONTROL SMART sensors to the 
fieldbus. Measurement values are transmitted at up to 500 Hz. 
Please refer to the TechNote T026 (scanCONTROL fieldbus integration) for more de-
tails.

Summary of Contents for scanCONTROL 25 BL Series

Page 1: ...d exposure of sensor to aggressive media detergents cooling emulsions Damage to or destruction of the sensor 2 Notes on CE Marking The following apply to the scanCONTROL 25xx BL measuring system EU Directive 2014 30 EU EU Directive 2011 65 EU The measuring system is designed for use in industrial applications The measuring system satisfies the requirements if the guidelines in the operating inst r...

Page 2: ...st be attached before the device is put into operation for the first time i If both warning labels are covered over when the unit is installed the user must ensure that supplementary labels are attached Laser Class 2M The sensors fall within laser class 2M IIM The laser is operated on a pulsed mode the maximum optical power is 8 mW Laser radiation Close your eyes or immediately turn away if the la...

Page 3: ...422 11 Gray Pink In1 6 Yellow Switching input In1 GND In1 4 Green Ground connection In1 In2 5 Pink Switching input In2 GND In2 8 Gray Ground connection In2 In3 10 Purple Switching input In3 GND In3 7 Black Ground connection In3 Screen Housing Black Not electrically connected to GND 2 3 4 5 6 7 8 9 1 10 11 12 GND galvanically isolated from In1 In2 In3 RS422 Laser on off Laser on off Input galvanica...

Page 4: ...switching inputs together via software between LLL low voltage TTL logic and HLL high voltage HTL logic LLL Low 0 V 0 8 V high 2 4 V 5 V internal pull up 10 kΩ connected to 5 V HLL Low 0 V 3 V high 11 V 24 V up to 30 V are permissible internal pull up 10 kΩ connected to 24 V Pulse duration 5 µs External Laser Switch off Optional The external laser switch off is implemented as a hardware solution a...

Page 5: ...P address in the link local net 169 254 x x No collision detection is implemented This is also the default setting The sensor supports DHCP This setting is activated by default and has priority over search the link local net The scanCONTROL 25xx BL sensor supports Power over Ethernet If the sensor is connected to a POE capable network adapter switch and you also use the power supply of the multifu...

Page 6: ...ools The following minimum system requirements are necessary Windows 8 or 8 1 Windows 10 each 32 bit and 64 bit 1 GHz processor or faster 32 bit and 64 bit 1 GB RAM recommended 4 8 GB Screen resolution 1024 x 768 recommended 1920 x 1080 scanCONTROL 3D View The following minimum system requirements are necessary Windows 8 or 8 1 Windows 10 each 64 bit 1 GHz processor or faster 64 bit 1 GB RAM recom...

Page 7: ... Close unused connection plugs with the included protective caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds Now you can operate the scanCONTROL measuring system with the scanCON TROL software packages i Operating the sensors via Ethernet may require the IP settings of the PC sensor or the firewall settings ...

Page 8: ...ssed via GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast integration into applications C C C and others Please refer to the respective SDK documentation for further information on accessing the profile data 10 Transmitting Measurement Results scanCONTROL 25xx BL offers the following options for transmitting measurement results Ethernet interface Modbus TCP protocol U...

Page 9: ...these fieldbus systems Furthermore all scanCONTROL sensor settings can be set via the 2D 3D Gateway e g Laser on off or User Mode Sensor parameterization Supply voltage Triggering Encoder Synchronization Mode switching Sensor control Gateway parameterization USB Ethernet switch 2D 3D Gateway The 2D 3D Gateway can connect up to four scanCONTROL SMART sensors to the fieldbus Measurement values are t...

Page 10: ...2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler L1 L2 L3 N PE OU Filter module OU Fieldbus coupler 13 14 C D B A 750 626 Ñ 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP System supply Field supply 230 V 24 V 230 V 24 V 12 scanCONTROL 25xx BL with 2D...

Page 11: ...tal output terminals need a field supply of 5 VDC or 24 VDC depending on the module type After mounting the modules install the required wiring Connect the System supply out contacts of the OU Filter module to the System supply in contacts of the OU Fieldbus coupler 0 V and 24 V Connect the system supply in of the OU Filter module to the power supply 0 V and 24 V Connect the field supply in of the...

Page 12: ...or and free cable ends Calibration protocol assembly instructions 2 Protective caps 14 Additional Information Please refer to the enclosed online documentation the Status and Error Messages and Notes sections in the scanCONTROL Configuration Tools operating instructions You will find details about the individual programs in the respective operating instructions or in the operating instructions of ...