Page 10
Functional Principle, Technical Data
optoCONTROL CLS-K
2.3
Range / Scanning Range
One Way
3
Sensor
3
Fiber strand
ø mm
Range
mm (type)
1
Minimum target size
(type)
Fiber strand
ø mm
Scanning range
mm (type)
1 2
0.6
90
≤ 0.05
0.6
≤ 10
1.0
200
≤ 0.1
1.0
≤ 30
1.5
500
≤ 0.1
1,5
≤ 80
2.5
1700
≤ 0.2
2.5
≤ 165
3.0
2000
≤ 0.3
3.0
≤ 180
2.4
Functions
The sensor optoCONTROL CLS-K supports following functions:
- Precise and reliable detection of targets
- Low drift by transmitter monitoring, thereby particularly suitable for measurement tasks.
- High switching frequency and short response time
- Sensor monitoring possible via analog signal
- Scanning distance up to 200 mm
4
- Range up to 2 m
4
-
Switching output: NPN, PNP, optocoupler, relays (depending on the model
-
Drop-out delay 5 - 100 ms adjustable (optional)
- Stable long-term behavior by controlling the transmitter diode emission
- Large selection of fiber optics available, see Chap.
The amplifiers CLS-K-61/-63 offer the possibility of spreading a signal range particularly important for the
solution of application on the entire analog range.
1) With 90° angular sensor mechanism reduced range
2) Related on Kodak white 90 %
3) See catalog optoCONTROL CLS-K
4) Depending on the fiber strand diameter