4. Installation and Assembly
4.1 Precautions
No sharp or heavy objects should be allowed to affect the cable sheath of the
sensor cable, the supply cable and of the output cable. All plug-in connections
must be checked for firm seating before starting operation.
4.2 Sensor
Type designation:
LS04
Construction:
The front part of the sensor with encapsulated coil
consists of electrically non-conducting materials.
Important:
In the radial direction metal parts in the vicinity may
behave similar to the measurement object,
rendering the measurement result inaccurate.
Legend:
mm
(inches)
Installation and Assembly
Fig. 4.2: Bonding the sensor into the injection body
i
IMPORTANT!
The sensor needs to be
bonded into the injection
body for high pressure
applications.
Fig. 4.1: Sensor Dimensions LS04 with integral cable
3.42
(.13)
2.42
(.10)
ø2.6
(.10)
ø0.5 (.02)
-0.05
R 0.1
70 ° ±0.2 °
Integral cable
length: 500 (20)
Honed
ø3.5
(.14)
Injection body
Sensor LS04
Mounting screw
Cold-cured adhesive