Overview of Mechanical Components
thicknessCONTROL MTS 8202.LLT / 4350127.347
3.4
Cable carrier
The cable carrier (1)
is attached to the base frame and supplies power to
all the components that are on the base frame. These develop a “polygon effect” during
movement, because individual chain connections are kinked. In a precise measuring
system, this effect negatively affects the measured result. For this reason, a special cable
drag that does not have a polygon effect is used. This ensures smooth running and pre-
cise measurements.
1
1 Cable carrier
Fig. 14 Cable carrier
3.5
Compressed Air Supply
The compressed air is used for the movement of the calibration part
.
Commissioning work performed by the customer:
Connect the compressed air supply (2)
1
2
1
Filter control valve with pressure
sensor
2
Compressed air connection
Fig. 15 Maintenance unit housing
The maintenance unit consists of a filter control unit for preparing the compressed air
and generating the working pressure. The compressed air is monitored electronically.
In the event of a drop in the nominal pressure from 5 bar to under 4 bar, a signal is sent
to the measuring system’s controller. The controller forwards this information to the user
interface.
Summary of Contents for 4350127.347
Page 1: ...thicknessCONTROL MTS 8202 LLT C frame Non contact thickness measurement Operating Instructions...
Page 10: ...Page 10 Overview Technical Data Safety Instructions thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 56: ...Page 56 Installation and Initial Operation thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 64: ...Page 64 Maintenance Service Spare Parts Lists thicknessCONTROL MTS 8202 LLT 4350127 347...
Page 66: ...Page 66 Declaration of Incorporation thicknessCONTROL MTS 8202 LLT 4350127 347...