unrecoverable errors in the device configuration and void any warranty. Users take
utmost care while modifying these parameters. Contact Levelcon in case you need
assistance
Remember to hit Save before you close the window for the changes to load to the
memory.
UTC offset
This option lets you select the appropriate time zone. This helps in maintaining time locally on
the device and is used as a reference for setting time alarm. As an example if your time zone is
+5:30, please enter the value
5.5
as an offset
Daylight Sav
This option lets you enable or disable daylight saving time settings. Please select the
appropriate option from the drop down menu.
Mode
Mode should always be sim for a Starpin device. Any changes to this will render the device
unusable
Sensor Type ( F100M device only)
The device is capable of communicating with 0-5 V and 4-20 mA type analog sensors. If you are
using an analog sensor with the device, please select the appropriate sensor type. By default,
the device is configured for 0-5 V type sensors.
ADC Wait(s) ( F100M device only)
This parameter enables you to set the number of seconds the device queues up the sensor for
a reading before it collects the sensor level data from the sensor. The Default value is 0
seconds. This should only be increased if using a non-contact sensor such as a radar gauge,
sonic sensor or laser sensor.
Shock Thresh
This parameter enables you to set the shock threshold. evel data from the sensor. The Default
value is 40. Do not change this value without consulting the LevelCon team
Warning : Entering value greater than 0 will enable the shock sensor and may drain