MICRO-AIR OM550DD Owner'S Manual Download Page 6

 

 

 

OM550DD 
PARTS LIST 

 

 

ITEM 

PART NO. 

DESCRIPTION 

 

ITEM 

PART NO. 

DESCRIPTION 

1. 

34451-01 

Cabinet Weldment 

 

9. 

P3027 

1/2 HP Blower Assy. 

2. 

34461-01 

Mounting Bracket 

 

 

P3028 

3/4 HP Blower Assy. 

3. 

34462-01 

Door 

 

10. 

39036-01 

Minihelic Gauge Kit 

4. 

30473-01 

Door Handle 

 

11. 

34465-01 

Gauge Cover Plate (Not Shown) 

5. 

34459-01 

Top Plate 

 

12. 

P1363 

115/230VAC Power Cord (Not Shown) 

6. 

P3649 

4-Prong Knob 

 

13. 

P3029 

120VAC Switch (1-Phase Only) 

7. 

P3020 

1/2 HP 115/230VAC 1-Phase Motor 

 

14. 

30386-02 

Switch Plate (1-Phase Only) 

 

P3023 

1/2 HP 208-230/460VAC 3-Phase Motor 

 

15. 

P3025 

Electrical Box (1-Phase Only) 

 

P7122 

3/4 HP 115/230VAC 1-Phase Motor 

 

 

 

 

 

P3021 

3/4 HP 208-230/460VAC 3/Phase Motor 

 

 

 

 

8. 

34460-01 

Spacer Plate 450 CFM 

 

 

 

 

 

34460-02 

Spacer Plate 550 CFM 

 

 

 

 

 

 

 
 
 

 

 

 

 

 

FILTER OPTIONS 

 

 

 

 

 

P3032 

95% Pleated Filter 

 

 

 

 

 

P3033 

3" Mist-X Pre-filter 

 

 

 

 

 

P3036 

2" Baffle Pre-filter 

 

 

 

 

 

P3035 

2" Mesh Pre-filter 

 

 

 

 

 

P3034 

1" Mesh Pre-filter 

 

 

 

 

 

P3038 

Maxi Grid Pre-filter 

 

 

 

 

 

 

  

Summary of Contents for OM550DD

Page 1: ...AIR CLEANERS OM55ODD OWNER S MANUAL CAUTION READ COMPLETE INSTRUCTIONS BEFORE OPERATING PLEASE FILE FOR FUTURE REFERENCE ...

Page 2: ...e weight of the unit Three feet of unobstructed exhaust space from the outlet of the unit Easy access to service panels and unit inlet As near as possible to the source of the oil mist unit to be captured 4 Mark location of the mounting holes on the surface to which unit is to be mounted see FIG 2 for hole pattern Drill or punch holes that are sized for mounting hardware to be used FIG 2 5 Lift OM...

Page 3: ...o the nearest outlet rated for 120 volts FIG 4 B THREE PHASE 208 230 460 VOLT 1 Conduit electrical connections should be made by a qualified electrician and must comply with local electrical codes CAUTION Be sure that the designated circuit breaker is off until all wiring has been completed NOTE It is recommended that a motor starter protector be used in the supply circuit to this unit See Wiring ...

Page 4: ...er IF the pockets are loaded with oil and dirt then remove the filter from the unit and insert a new filter 8 Start the unit The gauge should read low differential pressure and the unit operating properly GENERAL MAINTENANCE 1 Occasionally check the condition of the door seals for any leaks Replace if necessary 2 Check the blower bearings for unusual wear and the blower wheel for debris and dirt C...

Page 5: ...5 FIG 5 ...

Page 6: ... Cord Not Shown 6 P3649 4 Prong Knob 13 P3029 120VAC Switch 1 Phase Only 7 P3020 1 2 HP 115 230VAC 1 Phase Motor 14 30386 02 Switch Plate 1 Phase Only P3023 1 2 HP 208 230 460VAC 3 Phase Motor 15 P3025 Electrical Box 1 Phase Only P7122 3 4 HP 115 230VAC 1 Phase Motor P3021 3 4 HP 208 230 460VAC 3 Phase Motor 8 34460 01 Spacer Plate 450 CFM 34460 02 Spacer Plate 550 CFM FILTER OPTIONS P3032 95 Plea...

Page 7: ..._____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ __________________________________________________...

Page 8: ...__________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _______________...

Reviews: