Michell Instruments HygroSmart I7000XP User Manual Download Page 16

HygroSmart I7000XP User’s Manual

10

  

 

97481 Issue 1, January 2015

APPENDIX B

B.4 

RoHS2 Compliance

Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011

The Restriction of Hazardous Substances (RoHS) Directive places rules upon European manufacturers 

of electrical and electronic equipment. The directives’ aim is to reduce the impact that electronic 

devices have on the environment.

According  to  the  EC  Directive  2002/95/EC,  Michell  Instruments’  products  qualify  as  Category  9, 

Control and Monitoring Equipment. Under the 2002/95/EC Directive, Category 9 products are exempt

 

from compliance with the Directive.

However,  the  careful  design  of  all  Michell  Instruments’  products  takes  into  consideration  the 

requirements of the Directive and, wherever possible, compliance is achieved. All future products 

will  be  developed  entirely  using  compliant  materials.  Furthermore,  Michell  Instruments  is  taking 

active steps to remove non-compliant materials and components from existing products wherever 

these  may  occur.  Presently,  none  of  the  non-compliant  materials  are  known  to  occur  in  Michell 

Instruments’ products.

The new Directive 2011/65/EU (RoHS2) entered into force on 21 July 2011 and required all Member 

States to transpose the provisions into their respective national laws by 2 January 2013.

Under the provisions of the RoHS2 EU Directive 2011/65/EU (Article 3, [24]) defines ‘Control and 

Monitoring Equipment’ specifically as ‘monitoring and control instruments designed exclusively for 

industrial or professional use’.

RoHS2 EU Directive 2011/65/EU states the closing date for compliance of any Control and Monitoring 

Equipment product sold into the EU market place as 22nd July 2017.

However, the careful design policy of all Michell Instruments’ products continues to attain compliance 

in  the  shortest  practical  timescales  and  strives  to  ensure  that  less  than  0.1%  of  total  mass  per 

product,  of  all  non-compliant  materials,  appear  within  them.  Michell  Instruments  continues  to 

monitor suppliers and material sources to ensure that compliance of goods provided is maintained.  

January 2013

B.5 

Warranty

Unless otherwise agreed, the Supplier warrants that, as from the date of delivery for a period of 12 

months, the goods and all their component parts, where applicable, are free from any defects in 

design, workmanship, construction or materials.

The Supplier warrants that the services undertaken shall be performed using reasonable skill and 

care, and be of a quality conforming to generally accepted industry standards and practices.

Except  as  expressly  stated,  all  warranties  whether  express  or  implied,  by  operation  of  law  or 

otherwise, are hereby excluded in relation to the goods and services to be provided by the Supplier.

All warranty services are provided on a return to base basis. Any transportation costs for the return 

of a warranty claim shall reside with the Customer.

Summary of Contents for HygroSmart I7000XP

Page 1: ...HygroSmart I7000XP Interchangeable Sensor for RH Temperature User s Manual 97481 Issue 1 January 2015...

Page 2: ...this information when contacting Michell Instruments for service purposes Sensor Code Serial Number Invoice Date Location of Instrument Tag No Sensor Code Serial Number Invoice Date Location of Instru...

Page 3: ...copied or otherwise reproduced communicated in any way to third parties nor stored in any Data Processing System without the express written authorization of Michell Instruments Ltd HygroSmart I7000X...

Page 4: ...re 1 Operating Graph 2 Figure 2 Electrical Connections 3 Figure 3 HygroSmart I7000XP Sensor Pin Connector 4 Figure 4 Hygrosmart I7000XP Operating Conditions 7 Figure 5 Hygrosmart I7000XP Dimensions 7...

Page 5: ...is designed to be completely safe when used with options and accessories supplied by the manufacturer for use with the instrument Toxic Materials The use of hazardous materials in the construction of...

Page 6: ...ty s second T temperature V volt Warnings The following general warning listed below is applicable to this instrument It is repeated in the text in the appropriate locations Where this hazard warning...

Page 7: ...ive humidity and temperature in a wide spectrum of industrial and heavy industrial applications The sensor incorporates the latest HygroSmart 3 technology providing excellent performance across a wide...

Page 8: ...ensor must be made bearing in mind the effectiveness of air circulation The point at which the sensor is installed must be typical of the surrounding environment where the measurements of relative hum...

Page 9: ...t I7000XP Pin 1 Not Connected 2 Power Supply 3 Power Supply ve 4 Output Voltage RH 5 Output Temperature PT100 6 Output Temperature PT100 7 Output Temperature PT100 PT100 5 1 2 3 4 6 7 PT1000 PT100 PT1...

Page 10: ...he protection filter mounted on the measurement probe body NOTE Be careful not to apply any force to the filter protection cage 3 Taking care not to bend the male pins on the sensor electrical connect...

Page 11: ...HygroSmart I7000XP User s Manual Michell Instruments 5 APPENDIX A Appendix A Technical Specifications...

Page 12: ...Measurement Range 40 to 85 C 40 to 185 F Temperature Accuracy 0 2 C Temperature Resolution Infinite Electrical Specifications Output Signal White housing 0 1 V Black housing 0 2 1 V Temperature Output...

Page 13: ...NDIX A A 1 Operating Conditions 25 40 0 50 25 70 85 75 50 100 RH Temp C Maximum mixing ratio 250g water kg dry air Figure 4 Hygrosmart I7000XP Operating Conditions A 2 Dimensions 17 5mm 0 69 12mm 0 47...

Page 14: ...HygroSmart I7000XP User s Manual 8 97481 Issue 1 January 2015 APPENDIX B Appendix B Quality Recycling Warranty Information...

Page 15: ...which may be harmful to the environment Similarly we are increasingly using recyclable and or recycled material in our business and products wherever it is practical to do so To protect natural resour...

Page 16: ...EU Directive 2011 65 EU Article 3 24 defines Control and Monitoring Equipment specifically as monitoring and control instruments designed exclusively for industrial or professional use RoHS2 EU Direc...

Page 17: ...intains a hazardous material register in which MSDS data sheets are collated and we will check that our suppliers will comply to REACH requirements for all materials and substances we use in the proce...

Page 18: ...g courses of action will be taken If the fault is covered under the terms of the warranty the instrument will be repaired at no cost to the owner and returned If Michell Instruments determines that th...

Page 19: ...HygroSmart I7000XP User s Manual Michell Instruments 13 APPENDIX C Appendix C Recommended Practices in Humidity Measurements...

Page 20: ...ichell Instruments care instructions for the instrument Some instruments need routine cleaning or other maintenance Before using any solvent cleaner check with Michell Instruments that this will not h...

Page 21: ...of the air between the droplets Such results may exceed 100 RH or may be impossible to interpret meaningfully Droplets of liquid also damage some electrical types of humidity sensor Filtering the air...

Page 22: ...rials At low humidity anything much below a dew point of 0 C the amounts of water given off by organic and porous materials can dramatically affect the value of humidity The lower the level of moistur...

Page 23: ...d Filters and saturation guarding may protect the sensor but these actions carry a risk of damage by condensation or other contamination Protective filters can slow the response time of sensors This c...

Page 24: ...HygroSmart I7000XP User s Manual 18 97481 Issue 1 January 2015 APPENDIX D Appendix D Return Document Decontamination Declaration...

Page 25: ...cals YES NO Radioactive substances YES NO Other hazards YES NO Please provide details of any hazardous materials used with this equipment as indicated above use continuation sheet if necessary Your me...

Page 26: ...http www michell com...

Reviews: