background image

DT722 User’s Manual

Michell Instruments

 

 

11

APPENDIX C

Appendix C 

Return Document & Decontamination Declaration

     

 

 F0121, Issue 2, December 2011

'HFRQWDPLQDWLRQ&HUWL¿FDWH

IMPORTANT NOTE:  Please complete this form prior to this instrument, or any components, leaving your 

site and being returned to us, or, where applicable, prior to any work being carried out by a Michell 

engineer at your site.

Instrument

Serial Number

Warranty Repair?

YES

NO

Original PO #

Company Name

Contact Name

Address

Telephone #

E-mail address

Reason for Return /Description of Fault: 

Has this equipment been exposed (internally or externally) to any of the following?

Please circle (YES/NO) as applicable and provide details below

Biohazards

YES

NO

Biological agents

YES

NO

Hazardous chemicals

YES

NO

Radioactive substances

YES

NO

Other hazards

YES

NO

Please provide details of any hazardous materials used with this equipment as indicated above (use continuation sheet 

if necessary)

Your method of cleaning/decontamination

Has the equipment been cleaned and decontaminated?

YES

NOT NECESSARY

Michell Instruments will not accept instruments that have been exposed to toxins, radio-activity or bio-hazardous 

PDWHULDOV)RUPRVWDSSOLFDWLRQVLQYROYLQJVROYHQWVDFLGLFEDVLFÀDPPDEOHRUWR[LFJDVHVDVLPSOHSXUJHZLWKGU\
JDVGHZSRLQWƒ&RYHUKRXUVVKRXOGEHVXI¿FLHQWWRGHFRQWDPLQDWHWKHXQLWSULRUWRUHWXUQ

Work will not be carried out on any unit that does not have a completed decontamination declaration.

Decontamination Declaration

I declare that the information above is true and complete to the best of my knowledge, and it is safe for Michell 

personnel to service or repair the returned instrument.

Name (Print)

Position

Signature

Date

 

Summary of Contents for DT722

Page 1: ...DT722 Duct Mount RH Temperature Transmitter User s Manual 97332 Issue 2 January 2018...

Page 2: ...formation when contacting Michell Instruments for service purposes Transmitter Code Serial Number Invoice Date Location of Instrument Tag No Transmitter Code Serial Number Invoice Date Location of Ins...

Page 3: ...Ltd and may not be copied or otherwise reproduced communicated in any way to third parties nor stored in any Data Processing System without the express written authorization of Michell Instruments Ltd...

Page 4: ...1 Electrical Connections 2 3 CALIBRATION AND ADJUSTMENT PROCEDURE 3 3 1 Calibration and Adjustment 3 Figures Figure 1 DT722 1 Figure 2 Electrical Connections 2 Figure 3 Connections 3 Figure 4 Dimensio...

Page 5: ...dous materials in the construction of this instrument has been minimized During normal operation it is not possible for the user to come into contact with any hazardous substance which might be employ...

Page 6: ...b pound s mA milliampere mm millimeters percentage oz ounce s RH relative humidity T temperature V Volts Warnings The following general warning listed below is applicable to this instrument It is repe...

Page 7: ...le measurement and control of humidity and temperature is required Figure 1 DT722 1 1 Features Designed for accurate measurement in a harsh environment Can withstand temperatures up to 150 C 300 F Sta...

Page 8: ...NOT CONNECT for calibration only Green Pin 4 Output 1 RH 4 20 mA max 500 Pin 5 DO NOT CONNECT for calibration only NOTE Even though the DT722 has a 5 pin connector the standard connection cable A0000...

Page 9: ...ore frequent calibration is recommended A humidity generator Michell Instruments S503 S904 or Optical used in combination with a general reference handheld hygrometer is ideal for a quick and accurate...

Page 10: ...DT722 User s Manual 4 97332 Issue 2 January 2018 APPENDIX A Appendix A Technical Specifications...

Page 11: ...fications Output Signal 4 20 mA Supply Voltage 8 to 32 V DC Supply Voltage Influence 0 01 RH V typical Operating Specifications Operating Humidity Probe Housing Storage 10 to 95 RH non condensing Oper...

Page 12: ...DT722 User s Manual 6 97332 Issue 2 January 2018 APPENDIX A Dimensions Figure 4 Dimensions...

Page 13: ...DT722 User s Manual Michell Instruments 7 APPENDIX A This drawing is actual size and can therefore be photocopied and used as a template when mounting the instrument Figure 5 Template...

Page 14: ...DT722 User s Manual 8 97332 Issue 2 January 2018 APPENDIX B Appendix B Quality Recycling Warranty Information...

Page 15: ...ves Full information can be found on our website at www michell com compliance This page contains information on the following directives ATEX Directive Calibration Facilities Conflict Minerals FCC St...

Page 16: ...DT722 User s Manual 10 97332 Issue 2 January 2018 APPENDIX C Appendix C Return Document Decontamination Declaration...

Page 17: ...als YES NO Radioactive substances YES NO Other hazards YES NO Please provide details of any hazardous materials used with this equipment as indicated above use continuation sheet if necessary Your met...

Page 18: ...DT722 User s Manual 12 97332 Issue 2 January 2018 APPENDIX D Appendix D Recommended Practices in Humidity Measurements...

Page 19: ...s may require from only a few minutes to many hours Follow Michell Instruments care instructions for the instrument Some instruments need routine cleaning or other maintenance Before using any solvent...

Page 20: ...t must be avoided These can result in overestimates of the humidity of the air between the droplets Such results may exceed 100 RH or may be impossible to interpret meaningfully Droplets of liquid als...

Page 21: ...ow humidity anything much below a dew point of 0 C the amounts of water given off by organic and porous materials can dramatically affect the value of humidity The lower the level of moisture the more...

Page 22: ...ilters and saturation guarding may protect the sensor but these actions carry a risk of damage by condensation or other contamination Protective filters can slow the response time of sensors This can...

Page 23: ...signed to be in conformance with the relevant sections of the following standards or other normative documents EN61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requir...

Page 24: ...http www michell com...

Reviews: