background image

PREPARATION & OPERATION

WARNING!  Follow the instructions given in
this booklet and the training given by your su-
pervisor for the safe operation of this machine.
Failure to do so can result in personal injury
and/or damage to the machine or property.

RECEIVING THE EQUIPMENT

Inspect equipment immediately and report any
damage or missing parts:
• Chassis – pump plate, squeegee and wheel
condition.

APPLICATIONS

Recommended surfaces:
• Vinyl and ceramic tile
• Sealed or finished concrete floors
• Wood, stone and terrazzo

TRANSPORT OF EQUIPMENT TO SITES

• 

Transport Position:

 The machine should be trans-

ported with the front swivel caster on the ground and
the chassis should be in the “up” or transport position.
Step on the foot pedal located on the right side of the
foot bar to place chassis in transport position.
• Do not drag squeegee across parking lots or thresh-
olds.
• Never lift tank by gripping the lid retainer ring.

OPERATION

1. Operating Position: 

Press down on the footbar

and lift on handle until chassis is locked down into the
operating position. Do not press the foot pedal located
on the right side of the foot bar.

2. Squeegee:

 Push the machine a few feet for-

ward until squeegee is laid out. A side to side motion
will help lay out squeegee for pick-up.

3. Solution Retrieval:

 A normal walking speed

assures nominal performance. The faster you go,
the better the machine works. If the pump stops
working, refer to TROUBLESHOOTING. When
foam escapes through breather hole in lid, the tank
is full and must be emptied. See CLEANING UP.

Note: If the floor is not being wiped dry, the squee-
gee may need adjustment. See TROUBLESHOOT-
ING.

4. Transport Upon Completion:

 Return the

chassis to the “transport” or “up” position. Any liq-
uid residue can be easily mopped up.

5. Clean Equipment:

a) Drain the tank - locate discharge valve at the front
of tank. Position for proper draining. Lift “T” handle
to regulate solution discharge. Tip machine forward
for complete drainage. Take care not to damage squee-
gee when draining.

DANGER! Solution will discharge in a large
steady stream with some pressure. Wear protec-
tive eye wear and avoid skin contact with all
chemicals used in this tank.

b) Rinse tank with warm water.
c) Remove return bellow from the top of the pump to
drain solution that is past the pump. Locate hose clamp
on top of pump and loosen, then slide tube off.
d) Tilt machine back to expose undercarriage for
cleaning. To tilt - rest unit on its’ foot bar and handle.
e) Rinse wheels, chassis and squeegee.
f) Drain pump by gently pressing on the inlet flapper
valve located in the center of the pump plate.
g) Flushing Pump: Hold a hose next to the inlet flap-
per valve while simultaneously activating the pump by
turning a drive wheel. Be sure to drain excess solution
from pump.
h) Reinstall return tube and tighten hose clamp.

6. Storage:

 It is very important to 

drain all liquid

from the unit if it is to be stored or transported in freez-
ing conditions.

3

Summary of Contents for GULPER 360

Page 1: ...9312 or 800 331 3339 MI OH IN only 2011 N High St Lansing Michigan 48906 Fax 517 484 9836 Email CustServ Michco com Web site www Michco Com Parts Web site www FloorMachineParts Com Order Parts on Line...

Page 2: ...uip ment furniture or buildings For new books write to Pacific 2259 S Sheridan Muskegon MI 49442 6252 Carefully inspect all components to ensure that there is no concealed freight damage If such damag...

Page 3: ...N WAREHOUSE TYPE AREAS 5 THE OPERATOR MUST COMPLETELY UNDERSTAND ALL INSTRUCTIONS WARNINGS AND OPERATING PROCEDURES BEFORE USING THIS MACHINE 6 THIS MACHINE MUST BE MAINTAINED IN ACCORDANCE WITH THIS...

Page 4: ...hine works If the pump stops working refer to TROUBLESHOOTING When foam escapes through breather hole in lid the tank is full and must be emptied See CLEANING UP Note If the floor is not being wiped d...

Page 5: ...three bolts which at tach the squeegee will also adjust the squeegee height Turn the bolts clockwise to raise the squeegee or counter clockwise to lower the squeegee A 1 2 turn should be enough Be su...

Page 6: ...ARC KEEP LEVEL WITH FLOOR KEEP FLAT ON FLOOR FIGURE 1 CORRECT SQUEEGEE PROFILE 5 MAINTENANCE FIGURE 2 PUMP PLATE CLEARANCE TO FLOOR FLOOR 0 125 OR THE APPROX THICKNESS OF 2 QUARTERS PUMP DETAIL APPROX...

Page 7: ...TTOM VIEW 7 1 2 not shown 3 4 5 6 1 279704 Caster 2 1 2 279401 Gate Valve 1 1 2 1 3 279702 Caster 4 1 4 279703 Wheel 8 2 5 279201 Wheel Driver Tab 2 6 278502 Squeegee Assembly 1 7 276601 Pump Plate 1...

Page 8: ...03 Chassis Spring 1 25 277001 Foot Pedal 1 26 271302 Center Adjusting Bolt 1 27 277002 Pump Assembly 1 28 271303 Bellow 10 1 29 920012 5 16 18 Esna Nut 4 30 273901 Handle 1 31 278602 Tank Grey 1 Pump...

Page 9: ...st be delivered to the authorized dealer with shipping and delivery charges prepaid If unable to locate the Dealer you may contact Pacific at the address listed herein for the location of the nearest...

Reviews: