background image

Mianyang Weibo Electronics Co.,Limited

No.7 Road 2 of Xianren Road Youxian District Mianyang City P.R. China

Tel: 86-816-2971265 Fax: 86-816-2281934

www.wb-my.com

[email protected]

4

4

10

+E

11

GND

Key

Key

Key

Key Technical

Technical

Technical

Technical Data:

Data:

Data:

Data:

1.

Input: AC 0~10V…0~1000V(measuring range extensible with outside connected resistors);

2.

Output: DC 0-20mA or 4-20mA

3.

Frequency range:

25Hz

5kHz

4.

Accuracy : 0.5%

5.

Input Impedance (R):

Measurement Ux

10V, Ri

Ux

×

1k

Ω

/V

Measurement Ux

10V, Ri

Ux

×

10k

Ω

/V

6.

Linear Range:0-120% of nominal input

7.

Responding Time: 300ms

8.

Over Load Capacity: 2 times of nominal input, continuous;

9.

Output voltage: 6V

10. static current: 13mA

11. Auxiliary Power:

+12VDC/+24VDC

12. Isolation Voltage: Input/output DC 2500V,1min

Input/Power DC 2500V,1min,
Output/Power DC 1500V,1min;

13. Output Ripple:

6mV

14. Drifting by Temperature: 300

×

10

-6

/

15. Ambient Temperature:-1

0

℃~

+50

16. Mounting : DIN Rail 35mm Mounting

Instruction

Instruction

Instruction

Instruction of

of

of

of Installation

Installation

Installation

Installation and

and

and

and Use

Use

Use

Use

1. The product has adopted structure compliance with EN50022; suitable for DIN rail

mounting NS35/7.5, NS35/15. Installation steps are as following (please reference to

dimensional drawing):

Step 1: Immobilize one side of product‘s mounting trough to the DIN mounting rail;

Step 2: Pull out the spring clasp;

Step 3: Place whole mounting trough to the DIN mounting rail properly;

Step 4: Release spring clasp to make sure the installation.

2.

The product has calibrated before out of factory. After correctly wiring, it can be

powered and used immediately. But for further precise signal sampling, user need to

warm-up the product for 3 minutes before use.

a)

the auxiliary power requires isolation voltage≥2000V

AC

, DC current output ripple

10mV.

b)

When transducer measuring voltage exceed 1000V, it needs dividing input voltage

by using resistor which is provided by Weibo electronic. Different transducer uses

special resistor.

Summary of Contents for WBV414U05

Page 1: ... voltage voltage voltage voltage transducer transducer transducer transducer www wb my com wbdz yahoo cn Technical Service 86 816 2778271 Quality Complain 86 816 2278273 Fax Line 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of change a...

Page 2: ...nstructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary information Standard Standard Standard Standard applicati...

Page 3: ...awing Drawing unit unit unit unit mm mm mm mm Product Product Product Product Terminal Terminal Terminal Terminal Identification Identification Identification Identification Drawing Drawing Drawing Drawing Terminal Terminal Terminal Terminal definition definition definition definition table table table table 1 4 U 3 U 7 GND1 8 Iz DC current output Iz Auxiliary power ground GND 600V AC voltage inpu...

Page 4: ...50 16 Mounting DIN Rail 35mm Mounting Instruction Instruction Instruction Instruction of of of of Installation Installation Installation Installation and and and and Use Use Use Use 1 The product has adopted structure compliance with EN50022 suitable for DIN rail mounting NS35 7 5 NS35 15 Installation steps are as following please reference to dimensional drawing Step 1 Immobilize one side of prod...

Page 5: ...ing up the transducer for 3 minutes 1 Using output monitoring meter V1 to measuring the output of signal power source instrument set any input value which is within the measuring range of the transducer Ir e g if input value is 100V the output is 4 20Ma the expected output value Iz should be calculated as Iz 20mA 4mA Ur 100V 4mA 2 Using output monitoring meter V2 to measuring the output voltage V0...

Page 6: ...ding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wire and the output signal wire should be as short as possible For product intensive installation the space between each product should not be smaller than 10mm 5 Only use identified terminals 6 There is no lightening strike pre...

Reviews: