background image

Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital

Electrical Transducer since 1989

USER

USER

USER

USER MANUAL

MANUAL

MANUAL

MANUAL

WB

WB

WB

WBV414U05

V414U05

V414U05

V414U05 AC

AC

AC

AC voltage

voltage

voltage

voltage transducer

transducer

transducer

transducer

www.wb-my.com

[email protected]

Technical Service: 86 816 2778271

Quality Complain: 86 816 2278273

Fax Line: 86 816 2281934

ISO9001 ISO14000 ISO18000

Certified

Quality Warranty

Any quality problem found in WB series products, we offer

Three years free charge of repair the products, and six months guaranteed free charge of change and return the

products.

Summary of Contents for WBV414U05

Page 1: ... voltage voltage voltage voltage transducer transducer transducer transducer www wb my com wbdz yahoo cn Technical Service 86 816 2778271 Quality Complain 86 816 2278273 Fax Line 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of change a...

Page 2: ...nstructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary information Standard Standard Standard Standard applicati...

Page 3: ...awing Drawing unit unit unit unit mm mm mm mm Product Product Product Product Terminal Terminal Terminal Terminal Identification Identification Identification Identification Drawing Drawing Drawing Drawing Terminal Terminal Terminal Terminal definition definition definition definition table table table table 1 4 U 3 U 7 GND1 8 Iz DC current output Iz Auxiliary power ground GND 600V AC voltage inpu...

Page 4: ...50 16 Mounting DIN Rail 35mm Mounting Instruction Instruction Instruction Instruction of of of of Installation Installation Installation Installation and and and and Use Use Use Use 1 The product has adopted structure compliance with EN50022 suitable for DIN rail mounting NS35 7 5 NS35 15 Installation steps are as following please reference to dimensional drawing Step 1 Immobilize one side of prod...

Page 5: ...ing up the transducer for 3 minutes 1 Using output monitoring meter V1 to measuring the output of signal power source instrument set any input value which is within the measuring range of the transducer Ir e g if input value is 100V the output is 4 20Ma the expected output value Iz should be calculated as Iz 20mA 4mA Ur 100V 4mA 2 Using output monitoring meter V2 to measuring the output voltage V0...

Page 6: ...ding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wire and the output signal wire should be as short as possible For product intensive installation the space between each product should not be smaller than 10mm 5 Only use identified terminals 6 There is no lightening strike pre...

Reviews: