background image

Mianyang Weibo Electronics Co.,Limited

No.7 Road 2 of Xianren Road Youxian District Mianyang City P.R. China

Tel: 86-816-2971265 Fax: 86-816-2281934

www.wb-my.com

[email protected]

5

5

Instruction

Instruction

Instruction

Instruction of

of

of

of Installation

Installation

Installation

Installation and

and

and

and Use

Use

Use

Use

1. The product has adopted structure compliance with EN50022; suitable for DIN rail

mounting NS35/7.5, NS35/15. Installation steps are as following (please reference to

dimensional drawing):

Step 1: Immobilize one side of product‘s mounting trough to the DIN mounting rail;

Step 2: Pull out the spring clasp;

Step 3: Place whole mounting trough to the DIN mounting rail properly;

Step 4: Release spring clasp to make sure the installation.

2.

The product has calibrated before out of factory. After correctly wiring, it can be

powered and used immediately. But for further precise signal sampling, user needs to

warm-up the product for 3 minutes before use.

a)

The auxiliary power requires isolation voltage≥2000V

AC

, DC current output ripple

10mV, and multiple converters can share with one set auxiliary power together.

b)

Output signal (Iz) is designed to follow the impedance load value of

250

Ω

;

When

Resistance (R

1

) is less than

100

Ω

,

the user must add output current circuit a power

reduced resistance load R

0

to keep the summation of total impedance value is

between

100

Ω~

250

Ω

3.

Basic testing method for accuracy

(1) According to the terminal definition table to connect the testing circuit;

(2) The testing must to be done by under the following conditions

Auxiliary power:

24V

±

0.5

%,

ripple

5mV

Ambient temperature:

25

℃±

2

Relative humidity

: RH(45

75)

Accuracy for Signal Power Source instrument:

0.05

R

L

6

3

User system

Transducer

R

0

I

Z

Single
Phase
Power
Source

V-

V1

+

-

U+

U-

I

4

6

V3

Transducer

JK

1

JK

2

250Ω

Auxiliary

Power

6

3

1

+

-

V

2

GND

+E

R

Summary of Contents for WBP114S91

Page 1: ...tive active power power power power transducer transducer transducer transducer Single Single Single Single phase phase phase phase www wb my com wbdz yahoo cn Tel 86 816 2971265 Fax 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of chan...

Page 2: ...ng The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary informat...

Page 3: ...utput isolation high performance low drifting by temperature and low power consuming etc F F F Function unction unction unction realization realization realization realization schematic schematic schematic schematic drawing drawing drawing drawing Product Product Product Product Dimensional Dimensional Dimensional Dimensional Drawing Drawing Drawing Drawing unit unit unit unit mm mm mm mm Vin 4 6 ...

Page 4: ...Input frequency 50 60 Hz 2 Output 4mA 20mA 3 Accuracy 0 5 4 Input Impedance R When UX 10V RU UX 1KΩ V 5 Linear Range V 10 120 of nominal input I 1 120 of nominal input COSφ 0 1 lag 1 0 1 lead 6 Responding Time 300 ms 7 Over Load Capacity 2 times of nominal input voltage 1s 10s interval can repeat 10 times 20 times of nominal input current 1s 300s interval can repeat 5times 8 Output impedance 6V 9 ...

Page 5: ...tly wiring it can be powered and used immediately But for further precise signal sampling user needs to warm up the product for 3 minutes before use a The auxiliary power requires isolation voltage 2000VAC DC current output ripple 10mV and multiple converters can share with one set auxiliary power together b Output signal Iz is designed to follow the impedance load value of 250Ω When Resistance R1...

Page 6: ...ty other wise will damage the product 2 Pay attention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the product and carry with care to avoiding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wi...