Mianyang Weibo Electronics Co.,Limited

No.7 Road 2 of Xianren Road Youxian District Mianyang City P.R. China

Tel: 86-816-2971265 Fax: 86-816-2281934

www.wb-my.com

[email protected]

2

2

WBP114S41

WBP114S41

WBP114S41

WBP114S41 Active

Active

Active

Active power

power

power

power Transducer

Transducer

Transducer

Transducer

Safety

Safety

Safety

Safety claim

claim

claim

claim

The information in the safety claim of the equipment documentation is intended to ensure that

equipment is properly installed in order to maintain it in a condition.

It is assumed that everyone who would be associated with the equipment should be familiar with

the contents of that safety section, or this safety guide.

When electrical equipment is in operation, dangerous voltages will be present in certain parts of

the equipment (e.g. the input terminal). Failure to obverse warning notices, incorrect use, or

improper use may endanger personnel and equipment and course personal injury or physical

damage.

Before working in the terminal strip area, the equipment must be isolated.

Proper and safe operation of the equipment depends on appropriate shipping and handling, proper

storage, installation and commissioning, and on careful operation, maintenance and servicing.

The operating manual for the equipment gives instructions for its installation, commissioning, and

operation. However, the manual cannot cover all conceivable circumstances or include detailed

information on all topics. In the event of questions or specific problem, do not take any action

without proper authorization. Contact the appropriate WB technical sales office and request the

necessary information.

Standard

Standard

Standard

Standard application

application

application

application

1. Accuracy

Accurate degree is conformed to IEC688:1992

2. Safety

2.1 Overload capability

Overload capability is conformed to IEC688:1992

2.2 Isolation voltage

Can be endured testing voltage is conformed to Q/72085584-0.1-2004

2.3 Insulation impedance

The

insulation

impedance

is

no

less

than

20M

Ohm,

is

conformed

to

Q/72085584-0.1-2004

3. Electromagnetic Capability

3.1 Electromagnetic field immunity test according to IEC 61000-4-3:1995

3.2 Power frequency magnetic field immunity test according to IEC 61000-4-8:1993

Product

Product

Product

Product D

D

D

Description

escription

escription

escription and

and

and

and Application

Application

Application

Application

WBP114S41 adopts special made isolation module, professional MCU controller and the

technologies of high speed data synchronizing sampling and processing to isolate and convert

active power from single phase electric circuit

into a load independent output DC average

current signal 4-20mA.

Summary of Contents for WBP114S41

Page 1: ...er power transducer transducer transducer transducer Single Single Single Single phase phase phase phase www wb my com wbdz yahoo cn Technical Service 86 816 2778271 Quality Complain 86 816 2278273 Fax Line 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaran...

Page 2: ...erating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary information Stand...

Page 3: ...rifting by temperature and low power consuming etc F F F Function unction unction unction realization realization realization realization schematic schematic schematic schematic drawing drawing drawing drawing Product Product Product Product Dimensional Dimensional Dimensional Dimensional Drawing Drawing Drawing Drawing unit unit unit unit mm mm mm mm Input terminal DIN Mounting Rail Output termin...

Page 4: ... Hz 2 Output 4mA 20mA 3 Accuracy 0 5 4 Input Impedance R When UX 10V RU UX 1KΩ V 5 Linear Range V 10 120 of nominal input I 1 120 of nominal input COSφ 0 1 lag 1 0 1 lead 6 Responding Time 300 ms 7 Over Load Capacity 2 times of nominal input voltage continuous 20 times of nominal input current continuous 8 Maximum Load 6V 9 Auxiliary Power 12 Vdc 24Vdc 10 Current consumption for static status 25mA...

Page 5: ...tly wiring it can be powered and used immediately But for further precise signal sampling user needs to warm up the product for 3 minutes before use a The auxiliary power requires isolation voltage 2000VAC DC current output ripple 10mV and multiple converters can share with one set auxiliary power together b Output signal Iz is designed to follow the impedance load value of 250Ω When Resistance R1...

Page 6: ...ary power grade and polarity other wise will damage the product 2 Pay attention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the product and carry with care to avoiding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention...

Page 7: ...duct and any purchase made in six months Weibo will provide free charge of change and return the product if damage and problem caused by product quality Note Transportation fee of repaired and returned product will be borne by Buyer Product Product Product Product Input Output Input Output Input Output Input Output characteristic characteristic characteristic characteristic curve curve curve curve...