background image

 

Mianyang Weibo Electronics Co.,Limited 

No.98 Youxian East Road, Youxian District, Mianyang City, P.R. China 

Tel: 86-0816-2971265 Fax: 86-016-2281934 

www.weiboelectronic.cn

 

     

[email protected]

 

 

WBI417S41 TRUE RMS SENSING AC current transducer 

Safety claim 

The information in the safety claim of the equipment documentation is intended to ensure that 

equipment is properly installed in order to maintain it in a condition. 

It is assumed that everyone who will be associated with the equipment will be familiar with the contents 

of that safety section, or this safety guide. 

When electrical equipment is in operation, dangerous voltages will be present in certain parts of the 

equipment (e.g. the input terminal). Failure to obverse warning notices, incorrect use, or improper use 

may endanger personnel and equipment and course personal injury or physical damage. 

Before working in the terminal strip area, the equipment must be isolated. 

Proper and safe operation of the equipment depends on appropriate shipping and handling, proper 

storage, installation and commissioning, and on careful operation, maintenance and servicing. 

The operating manual for the equipment gives instructions for its installation, commissioning, and 

operation. However, the manual cannot cover all conceivable circumstances or include detailed 

information on all topics. In the event of questions or specific problem, do not take any action without 

proper authorization. Contact the appropriate WB technical or sales office and request the necessary 

information.  

Standard application 

1. Accuracy 

    Accurate degree is conformed to IEC688:1992 

2. Safety 

  2.1 Overload capability 

    Overload capability is conformed to IEC688:1992 

  2.2 Isolation voltage 

        Can be endured testing voltage is conformed to Q/72085584-0.1-2004 

 2.3 Insulation impedance 

        The insulation impedance is no less than 20M Ohm, is conformed to Q/72085584-0.1-2004     

3. Electromagnetic Capability   

        3.1 Electromagnetic field immunity test according to IEC 61000-4-3:1995 

        3.2 Power frequency magnetic field immunity test according to IEC 61000-4-8:1993     

Summary of Contents for WBI417S41

Page 1: ...ectric Isolated Transducer and Digital Electrical Transducer since 1989 USER MANUAL WBI417S41 TRUE RMS SENSING AC current transducer www weiboelectronic cn wbwm wbdz cn Tel 86 0816 2971265 Fax 86 0816 2281934 ISO9001 ISO14000 ISO18000 Certified Company ...

Page 2: ...and safe operation of the equipment depends on appropriate shipping and handling proper storage installation and commissioning and on careful operation maintenance and servicing The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the ...

Page 3: ...as certain advantages of total galvanic isolation between input output high accuracy low drifting by temperature and wide temperature bearable range etc Product Dimensional Drawing unit mm Aperture Size 4 mm Product Terminal Identification Drawing Input I 9 Auxiliary Power Output Ground GND Auxiliary Power E 1 3 4 Output Iz Non identified terminal cannot be used Mianyang Weibo Electronics Co Limit...

Page 4: ...4mV root mean square value output load is 250Ohm 13 Drifting by Temperature 200 10 6 14 Ambient Temperature Commercial grade 0 50 Industrial grade 25 70 15 Mounting DIN Rail 35mm Mounting or screw mounting Instruction of Installation and Use 1 The product has adopted structure compliance with EN50022 suitable for DIN rail mounting NS35 7 5 NS35 15 Installation steps are as following please referen...

Page 5: ...ollowing conditions Auxiliary power 24V 5 ripple 5mV Ambient temperature 25 5 Relative humidity RH 45 75 Accuracy for Signal Power Source instrument 0 05 Signal Source Transducer Power Supply 250Ohm 3 1 V1 R 3 6 V2 3 Warming up the transducer for 3 minutes 4 using output monitoring meter V1 to measuring the output of signal power source instrument set a any input value which is within the measurin...

Page 6: ...ention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the product and carry with care to avoiding bump and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wire and the output signal wire should be as shor...

Reviews: