Mi Solar Monitor-ISO SNMP User Manual Download Page 3

 

3 | 

P a g e

 

 

Solar Monitor -

ISO

 

SNMP

 

Mi 

 

The unit supports SNMP V1 and SNMP V2C communication platform to be 
compatible with SNMP monitoring software platforms and the 

free 

Mi-SNMP Monitor 

software for Microsoft Windows.(download from 

https://microinstruments.co.za/software.html

) 

The Solar Monitor system functions on 12V and 24V battery bank systems only 

        

    

 

The Solar Monitor can also be easily connected to the external optional 5 way relay 
module to reset or control equipment at the remote site through the Relay port. 

The unit also have a potential free normally closed alarm contact input, this can 
assist with attempted solar panel theft by connecting an Alarm magnetic reed switch 
to the alarm input. 

The system can also report both battery voltages separately as well as the total 
voltage for a 24V system if the 12V centre tap wire is connected-**see system 
connections page. 

 

Solar Panel voltage not monitored ! 

Some Solar Regulators are 

common negative

 regulators where the positive line 

from the PV input is being controlled to the charge output, other regulators are 

common positive

 regulators where the negative line is being controlled from the PV 

input to the charge output. 

The problem comes in with 

Common positive

 regulators that controls the negative 

input line of the solar panel, the moment the negative from the solar panel is 
connected to the system ground in order to measure the solar panel input voltage, a 
direct path between negative coming from the solar panel and the battery negative is 
established resulting in a direct connection between the solar panel and the battery 
and 

is actually “

Bridging out

” the control regulator resulting in 

over charging

 of the 

batteries. 

Thus 

we don’t measure the PV input voltage but the PV input amps only.      

 

 

Summary of Contents for Solar Monitor-ISO SNMP

Page 1: ...s for 12V and 24V Battery systems With Optional external relay module INDEX 1 SYSTEM DESCRIPTION 2 SYSTEM CONNECTIONS 3 RESET TO DEFAULTS AND PASSWORDS 4 OPTIONAL 5 WAY RELAY MODULE 5 WEB PAGES 6 TFTP...

Page 2: ...m changes any existing solar regulator into a smart monitoring device Solar Panel input current Battery charge current Load current battery voltage and temperature data is available via embedded web p...

Page 3: ...al voltage for a 24V system if the 12V centre tap wire is connected see system connections page Solar Panel voltage not monitored Some Solar Regulators are common negative regulators where the positiv...

Page 4: ...4 P a g e Solar Monitor ISO SNMP Mi 2 SYSTEM CONNECTIONS USING LOAD OUTPUT FROM REGULATOR SYSTEM CONNECTIONS NO LOAD OUTPUT USED FROM REGULATOR...

Page 5: ...nected to a 24V battery system the centre tap blue wire in drawing have to be connected IMPORTANT NOTE The Alarm input is a potential free contact input only and NO voltages should be injected here Pe...

Page 6: ...itor via a 10way ribbon cable supplied with the relay module Relay s is rated at 10Amps 220Vac Relay 1 2 3 can only be toggled to activate for 10sec then return to the off position again and is used t...

Page 7: ...the status of Relays 5 to 1 is given and indicated by a green dot if the relay is active powered A module heartbeat indication by a yellow dot flashes once per second as the software runs through the...

Page 8: ...olar Monitor ISO SNMP Mi STATUS PAGE Temperature sensor is displayed in degrees Celsius Solar panel input current Charge current Load current Battery 1 voltage Battery 2 voltage 24V system Total batte...

Page 9: ...toggled for 10 second periods and is typically used to reset radios or routers without logging yourself out completely from the remote site after a relay was accidently switched relay 1 to 3 will ret...

Page 10: ...ly be left unaltered NETWORK CONFIGURATION PAGE MAC address is displayed and cannot be changed Setup IP address Gateway and Subnet Mask and user password After the configuration was saved the Reboot i...

Page 11: ...ger software OID table number of services 11 1 3 6 1 4 1 45501 1 3 1 0 Relay 4 status integer 0 off 1 on 1 3 6 1 4 1 45501 1 3 2 0 Relay 5 status integer 0 off 1 on 1 3 6 1 4 1 45501 1 3 3 0 Total Bat...

Page 12: ...ng the equipment to indicate online offline status Graphing each device added will have its own graphical presentation of all measured data and is unit specific Email alerts Multiple email addresses c...

Page 13: ...t consumption with LAN port active 110mA 12Vdc 50mA 24Vdc Current sensors on Charge Load and Solar panel 75 Amp isolated non invasive current sensors 9mm OD cables max current sensors accept 9mm cable...

Reviews: