background image

 

 

 

10Mbs User control Ethernet interface for remote management. 

 

Each Port have led indication for port power status , led’s also indicates if the unit is connected in MODE B- 2pair 

power or PHANTOM MODE-4pair power mode for POE A and POE B. 

 

When POE A or POE B is connected in the MODE B mode – only the 

green

 led illuminates on the POE port 

When POE A or POE B is connected in the PHANTOM mode – the 

green

 and 

amber 

led illuminates on the POE port  

 

Rear view 

 

POE A is the master unit and POE B is the slave unit 

The unit will not work if Power is connected to POE B only – always use POE A power input 

RESET 

To factory reset the unit to the default 192.168.1.2 IP address , disconnect power from the unit , short circuit the 2 

pins carefully as indicated by the arrow on the backside , apply power to POE A , wait 10seconds , remove the short 

circuit across the 2 reset pins. 

Green pluggable terminals for power connection

:   

The unit can be powered from the 

same

 supply voltage or from 

two different

 supply voltages –see connection 

diagrams below  

 ** Reverse polarity connections could damage your POE connected equipment** 

Please be careful about correct polarity when connecting the power source  

 

Each POE group , POE A (ch1-4) and POE B (ch1-4) can be wired to function in the 

 (same or different modes) and the (same or different) voltages. 

MODES : 

MODE B

 = 2 pair powering over LAN cable 

PHANTOM

 = 4 pair powering over LAN cable   

Provision was made for the user to write the voltage for the POE A group and the POE B group onto the 

front facia of the unit to avoid confusion between different voltage supplies between the channels 

4+4 CHANNEL GB PASSIVE DC POE STRIP WITH MANAGEMENT –