10Mbs User control Ethernet interface for remote management.
Each Port have led indication for port power status , led’s also indicates if the unit is connected in MODE B- 2pair
power or PHANTOM MODE-4pair power mode for POE A and POE B.
When POE A or POE B is connected in the MODE B mode – only the
green
led illuminates on the POE port
When POE A or POE B is connected in the PHANTOM mode – the
green
and
amber
led illuminates on the POE port
Rear view
POE A is the master unit and POE B is the slave unit
The unit will not work if Power is connected to POE B only – always use POE A power input
RESET
To factory reset the unit to the default 192.168.1.2 IP address , disconnect power from the unit , short circuit the 2
pins carefully as indicated by the arrow on the backside , apply power to POE A , wait 10seconds , remove the short
circuit across the 2 reset pins.
Green pluggable terminals for power connection
:
The unit can be powered from the
same
supply voltage or from
two different
supply voltages –see connection
diagrams below
** Reverse polarity connections could damage your POE connected equipment**
Please be careful about correct polarity when connecting the power source
Each POE group , POE A (ch1-4) and POE B (ch1-4) can be wired to function in the
(same or different modes) and the (same or different) voltages.
MODES :
MODE B
= 2 pair powering over LAN cable
PHANTOM
= 4 pair powering over LAN cable
Provision was made for the user to write the voltage for the POE A group and the POE B group onto the
front facia of the unit to avoid confusion between different voltage supplies between the channels
4+4 CHANNEL GB PASSIVE DC POE STRIP WITH MANAGEMENT –
POE 4+4GM
Mi