background image

 Propane Patio Heater Manual 

       

 

 

 

                 

 

 

 

 

  9

ASSEMBLY FOR MH-0040-PM10 (BEFORE SERIAL # 5450 1014 00001)

ASSEMBLING THE HEATER

Note: Tools required: 7/16" Wrench, 3/8" Open End Wrench, Adjustable opening 

Wrench 8" long, Phillips screwdriver

1.  

Attach post to base assembly.

 Attach the Post to the post mounts 

using M5 x 12 Bolts (6 pcs).

2.  

Attach cylinder cover. 

Attach the Cylinder Cover to the post mounts.

3.  

Attach the upper pole to the lower pole

 by four M4 x 8 bolts.

4.  

Attach head assembly to post. 

Load Head Assembly by inserting 

Gas Hose into Post. Insert Head Assembly into Post. Tighten securely 

using M5x12 Bolts (4 pcs).

5.  

Assembly of reflector. 

Attach Reflector Cap to top of reflector (4 

pcs) using the M6 x 10mm Bolts (12 pcs), 6mm Washers (12 pcs) 

and M6 Nuts (12 pcs) as shown.

6.  

Attach the reflector 

assembly to top of head assembly, Load the 

Reflector Assembly to the top of the Head Assembly using M6 x 10 

(3 pcs), 6mm Washers (3 pcs).

7.  

Connect gas line to LP cylinder.

 Attach Gas Hose to the Regulator 

with 3/8” open end wrench and adjustable wrench, then fix it iwth 

the fixing chain. Attach Regulator to LP cylinder. Tighten securely, 

then move LP cylinder to the plate of the Base assembly.

8.  

Check for leaks.

 All factory connections of your Patio Heater have 

been checked. To check the connections of the Gas Hose / Regulator 

/ LP cylinder:

1. Make leak test solution by mixing 1 part liquid dish soap and 3 

parts water.

2. Spoon several drops (or use a squirt bottle) of the solution onto 

the Gas Hose/Regulator or the Regulator/LP cylinder connection

3. Inspect the connections and look for bubbles.
4. If no bubbles appear, the connection is safe. 

Do not use a flame 

to test for leaks!.

5. If bubbles appear, then there is a leak. Loosen and re-tighten the 

connection where bubbles are present.

9.  

Lower LP cylinder cover onto cylinder base. 

Lower the LP cylinder 

cover onto the Cylinder Base.

10.  

Disconnect LP cylinder when storing or transporting.

 Turn off 

heater and turn off valve on LP cylinder. Disconnect the Regulator 

and remove LP cylinder.

NOTE: Turn off valve on gas cylinder when heater is not in 

use.

pole support

fixing 
chain

tighten

cylinder

1.

2.

3.

4.

6.

7.

5.

Summary of Contents for MH-0040-PM10

Page 1: ... OF INJURY READ ENTIRE MANUAL BEFORE OPERATING THIS MANUAL IS AN IMPORTANT PART OF THE HEATER AND MUST REMAIN WITH THIS UNIT Propane Patio Heaters OPERATOR S MANUAL MH 0040 PM10 Copyright 2009 Mi T M Corporation 37 1070 E F S 102114 C US 247218 ...

Page 2: ...14 00001 10 11 OPERATION 12 LIGHTING INSTRUCTIONS 12 AFTER FIRST LIGHTING 12 WHEN HEATER IS ON 12 RELIGHTING 13 SHUT DOWN INSTRUCTIONS 13 MAINTENANCE 14 STORAGE 14 BETWEEN USES 14 DURING EXTENDED PERIODS OR WHEN TRANSPORTING 14 TROUBLESHOOTING 15 STATEMENT OF WARRANTY 16 WARNING NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Warning This product contains lead a ch...

Page 3: ... T M Patio Heater You can be assured your Mi T M Heater was constructed with the highest level of precision and accuracy Each component has been rigor ously tested by technicians to ensure the quality endurance and performance of this heater This operator s manual was compiled for your benefit By reading and following the simple safety installa tion and operation maintenance and troubleshooting st...

Page 4: ...sert or allow any foreign objects to enter any ventilation or exhaust opening as this may cause a fire or damage to the heater This heater is EXTREMELY HOT while in operation Bulk fuel storage should be a minimum of 25 ft from heaters torches portable generators or other sources of ignition All fuel storage should be in accordance with federal state or local au thorities having jurisdiction Never ...

Page 5: ... CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE AN LP CYLINDER NOT CONNECTED FOR USE SHALL NOT BE STORED IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE PROPOSITION 65 WARNING FUELS USED IN GAS WOOD BURNING OR OIL FIRED APPLIANCES AND THE PRODUCTS OF COMBUSTION OF SUCH FUELS CO...

Page 6: ...PT TO OPERATE THIS PATIO HEATER UNTIL YOU HAVE READ AND UNDERSTOOD ALL SAFETY PRECAUTIONS AND INSTRUCTIONS LISTED IN THIS MANUAL INCORRECT OPERATION OF THIS UNIT CAN CAUSE SERIOUS INJURY DO NOT ALTER OR MODIFY THIS EQUIPMENT IN ANY MANNER NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ...

Page 7: ...e 250 PSI max Manifold Pressure 11 W C Size Height 7 2 Size Diameter 32 5 16 Net Weight Lbs 59 Cylinder Required 20lb Reflector Assembly Head Assembly Post Cylinder Cover Cylinder Base FEATURES The Propane Patio Heater comes with safety features including anti tilt switch and auto shutoff switch The features of the Propane Patio Heater is shown ...

Page 8: ...or OUTDOOR use only If stored indoors detach and leave the LP cylinder outdoors 7 Never replace the regulator with any regulator other than the factory suggested replacement 8 This heater should be secured or moved inside if winds exceed 22 miles per hour to prevent damage to heater 9 Do not insert or allow any foreign objects to enter any ventilation or exhaust opening as this may cause a fire or...

Page 9: ...the Regulator with 3 8 open end wrench and adjustable wrench then fix it iwth the fixing chain Attach Regulator to LP cylinder Tighten securely then move LP cylinder to the plate of the Base assembly 8 Check for leaks All factory connections of your Patio Heater have been checked To check the connections of the Gas Hose Regulator LP cylinder 1 Make leak test solution by mixing 1 part liquid dish s...

Page 10: ... 20 Bolts 4 pcs Use flange cover after tightening bolts 3 Attachheadassemblytopost LoadHeadAssemblybyinsertingGasHoseintoPost InsertHeadAssembly into Post Tighten securely using M5x12 Bolts 4 pcs 4 Attach the upper pole to the lower pole by six M4 x 8 bolts 5 Assembly of reflector Attach Reflector Cap to top of reflector 4 pcs using the M6 x 10mm Bolts 12 pcs 6mm Washers 12 pcs and M6 Nuts 12 pcs ...

Page 11: ...mixing 1 part liquid dish soap and 3 parts water b Spoon several drops or use a squirt bottle of the solution onto the Gas Hose Regulator or the Regulator LP cylinder connection c Inspect the connections and look for bubbles d If no bubbles appear the connection is safe Do not use a flame to test for leaks e If bubbles appear then there is a leak Loosen and re tighten the connection where bubbles ...

Page 12: ...osition b Keep depressing the control knob put a long stem lighter into the ignition hole on the emitter screen To light the burner c Repeat step 4 FLAME CHARACTERISTIC The flame pattern at the emitter screen should be visually checked whenever heater is operated Normally the burner flame is blue but little yellow flame is acceptable If flames extend beyond surface of the emitter grid or the pheno...

Page 13: ...ob to the OFF position 2 Wait at least 5 minutes before attempting to relight 3 Repeat steps beginning with step 2 under Lighting Instructions SHUT DOWN INSTRUCTIONS 1 Push in and turn Control Knob to the OFF position 2 Turn gas valve on LP cylinder clockwise until tight to close WARNING ALWAYS BE SURE CONTROL KNOB IS OFF AND CYLINDER IS OFF WHEN LEAVING HEATER NEVER LEAVE THIS PATIO HEATER UNATTE...

Page 14: ...mpressed air may help clear away smaller particles 6 Carbon deposits may create a fire hazard Clean dome and emitter with warm soapy water if any carbon deposits develop At least ONCE A YEAR check the section of the hose inside the post 7 In salt air environments such as near an ocean corrosion occurs more quickly than normal Frequently check for corroded areas and repair them promptly STORAGE BET...

Page 15: ...w 2 Orifice blocked 3 Control valve is not ON 4 Thermocouple is bad 5 Pilot light assembly is bent or not in the correct location REMEDY 1 LP cylinder is near empty Refill LP cylinder 2 Remove and clean and replace if needed 3 Turn valve to ON 4 Replace thermocouple 5 Place pilot in proper position and retry ...

Page 16: ...examine the item and determine if defective Mi T M will repair or replace and return the item freight pre paid If Mi T M finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Mi T M disclaims all warranties for prod ucts that are purchased from sellers other than authorized reta...

Reviews: