28
Operator’s Manual
Maintenance
MAINTENANCE CHART:
To ensure satisfactory operation over an extended period of time, an engine requires normal maintenance at regular
intervals. The Periodic Maintenance Chart below shows periodic inspection and maintenance items and suitable intervals.
The bullet mark designates that the corresponding item should be performed at that interval.
NOTE: Some adjustments require the use of special tools or other equipment. An electronic tachometer will facilitate
setting idle and running speeds.
• The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever comes first.
•• The engine oil must be changed after the first 5 hours of operation and every 50 hours or 3 months, whichever comes first.
••• Service more frequently under dusty conditions.
Every 2 years, an Authorized Service Technician should check the safety valve, intake valves and delivery valves.
Procedure
Daily
Weekly
Monthly
100
Hours
200
Hours
Before
Storage
Check Pump Oil Level
x
Check Engine Oil Level
x
Oil Leak Inspection
x
Check Engine Air Filter
x
Drain Condensation in Air Tank (s)
x
Inspect Guards/Covers
x
Check for Unusual Noise/Vibration
x
Check for Air Leaks
x
Check cylinder and head fins for dust and dirt
x
Check battery electrolyte level
x
Check fuel lines (replace if necessary)
x
Clean Exterior of Compressor
x
Inspect Air Filter
x
Inspect Belt
x
Check Safety Relief Valve
x
Change engine oil (••)
x
Clean fuel filter
x
Clean dust and dirt from cylinder and cylinder head fins (•••)
x
Change Pump Oil (•)
x
Replace Air Filter
x
Check Engine Spark Plug
x
Add fuel stabilizer
x
Run unit dry
x
Summary of Contents for AGW-SH22-20M
Page 4: ...4 Operator s Manual Contents ...
Page 34: ...34 Operator s Manual Maintenance WIRING DIAGRAM AGW SR14 30M ...
Page 35: ...Operator s Manual 35 Maintenance WIRING DIAGRAM AGW SH22 20M ...
Page 73: ...Manual del Operador 73 Mantenimiento Diagrama de Cableado AGW SR14 30M ...
Page 74: ...74 Manual del Operador Mantenimiento Diagrama de Cableado AGW SH22 20M ...