MOUNTING (CONT.):
WALL MOUNT
1. Open enclosure door to access mounting holes.
2. Refer to Figure 4 to mark the locations of the three mounting holes on the
back panel of the generator.
3. Install screws through the three mounting holes built in the top two corners
and bottom center of the back panel of the generator.
4. Close enclosure after mounting is complete.
ELECTRICAL:
MAIN POWER
Your Mi-T-M Corona Discharge Ozone Generator has been pre-wired to your
oil/water separator.
NOTE:
Refer to the IMPORTANT SAFETY INSTRUCTIONS at the beginning
of this manual for important wiring information.
GROUNDING LUG
Using a 6-14AWG conductor, connect the Grounding lug on the right side of the
Mi-T-M Corona Discharge Ozone Generator to an appropriate earth contact.
PLUMBING:
1. Connect ¼” blue ozone tubing assembly to the barb at the bottom of the
ozone generator box.
2. Run other end of tubing assembly to the barb on the top of the ozone injector
mazzei of the water treatment system.
3. Make sure a check valve is installed and functioning properly between the
ozone injector and the ozone generator.
INSTALLATION
5.77”
3 x .25”
2.68”
12.40”