TROUBLESHOOTING
Knowledge of electrical applications is required for troubleshooting. Contact a certified electrician if you are
unsure of your ability to service the equipment. Improper servicing will void generator warranty.
SYMPTOM
PROBABLE
CAUSE
REMEDY
ELECTRICAL
"Main Power" light out when
No power to the generator module
Check circuit breaker at the power
recycling system is on.
from the power source.
distribution box.
Check for loose connections or
wiring
breaks
from
the
power
distribution
box
to
the
generator.
The fuse in the unit has blown and
needs
to
be
replaced.
The
fuse
is
a
replaceable
glass,
.25”X1.25”,
1amp, slo-blo type. Part number is
32-1195
..........................................................................................................................................................................................
GFCI has tripped
Check power cord.
Reset GFCI.
Ozone tube becomes
The high concentration of ozone as
This is normal and acceptable
yellow/brown and brittle.
well as environmental conditions like
as long as the tubing doesn’t
UV sunlight will deteriorate the hose
become cracked. Replace
over time.
ozone tube and check valves
every
1
or
2
years.
NOTE:
If GFCI or breaker continues
to
trip
after
reset,
call
1-800-553-9053
for
technical
assistance.