Manual setting / programming:
To enter the setting menu, press and hold the "+" and "-" keys for approx. 4 seconds while they are
switched off (no display).
You can switch between the different setting levels by repeatedly pressing the On/Off key (centre key). You
can change the values of the respective setting with the "+" and "-" keys.
The following setting options are available:
Nr.
Funktion
Einstellbereich
Standartwert
01
Temp. Calibration (calibration of the
temperature sensor)
-9°C - +9°C
0°C
02
Mode (heating or cooling mode)
0 = Cooling, 1 = Heating
0 = Cooling
03
Sensor Mode (External, or room sensor)
0 = Room, 1 = External
1 = External
04
Dead Band / Hysteresis (Switching
temperature range)
0.5 bis 9 °C
0.5 °C
05
Heat pump protection
0 = Aus, 1 = An
1 = An
06
Mode Select (PRG = Automatic, MAN =
Manuel)
0 = MAN Mode, 1 = PRG
0 = MAN Mode
07
Lock/Unlock (Key lock)
0 = Unlock, 1 = Lock
0 = Unlock
08
Reset (Reset to factory settings)
0 = No, 1 = Yes
0 = No
09/10
Software Version (Not changeable)
-
-
The configuration menu is left automatically after approx. 10 seconds without an entry.
Release the key lock:
To release the key lock (display shows only 7), press and hold keys "+" and "-" simultaneously for about 4
seconds.
The heat pump protection:
If the heat pump protection is activated, the thermostat switches the connected device on for approx. 30
seconds every 11 hours, regardless of the set temperature.