Venetian blinds Programming Guide
Delete transmitter channel from motor
Press
Stop button for
6
seconds
Button lighting on the
trans mitter flashes.
Teach-in readiness estab-
lished.
Select channel
Channel button lights up
+
Press Motor button and keep
pressed.
Additionally, within 3 seconds,
briefly press
Close button
.
Blind briefly moves up and
down once.
Release
Motor button
.
Press
Stop button
for 6 seconds
or wait for 20 seconds
Button lighting on the
trans mitter stops flashing.
Teach-in readiness ended.