2. Product Description
Diesel or Kerosene direct-fired mobile/portable space heater with open combustion chamber and indirect fired
mobile/portable space heater with close combustion chamber
3. Technical Specifications
Model
DH2-I-55
DH2-I-85
DH1-70
DH1-100
Heat Input* [kW] [Hs]
52.5
82,9
67.9
97.2
Air Flow Rating [m³/h]
2500
3900
2200
2700
Fuel Type
Diesel - Kerosene Diesel - Kerosene Diesel - Kerosene Diesel - Kerosene
Fuel consumption [l/h]
4.8
7.7
6.3
9.0
Fuel Nozzle size
1.00 gph-60°
1.50 gph-80°
1.35 gph-60°
1.75 gph-60°
Voltage [V]
230V 50Hz
230V 50Hz
230V 50Hz
230V 50Hz
Electrical Power rating [W]
720
900
580
700
Pump Pressure Setting [bar]
12.0
12.0
11.0
12.5
Current Rating [A]
3.2
3.9
2.6
3,1
Fuse Rating
T6.00 A
T6.00 A
T6.00 A
T6.00 A
Air collar setting [notch]
3
4
-
8
Dimensions
Net Weight (kg)
58.0
78
43.0
58
Length (mm)
1385
1650
1200
1470
Width (mm)
600
690
600
690
Height (mm)
785
1040
755
830
Tank Capacity (l)
55
110
55
110
Operating range (h)
~11
~14
~9
~12
Standard Accessories
Fuel gauge
yes
yes
yes
yes
Handle
1
1
1
1
Ambient thermostat
built-in
built-in
built-in
built-in
Malfunction detection signal
built-in
built-in
built-in
built-in
*Based on dedicated setting for standard condition (atmospheric pressure 1020 hPa and Temperature 20 °C).
4.
Assembling Instructions
Extract the heater from its carton. If the unit is anyhow
damaged, do not use it and contact your dealer.
The following accessories are supplied in the shipping
carton.
Pos.
Description
Qty
A
Handle
1
B
Screw M5
6
C
Heater body
1
D
Wheel shaft
1
E
Wheel
2
F
Spring washer
2
G
Spacer
2
H
Nut M5
6
I
Feet pipe
1
Fig.1