EYF Series Unvented Gas Log Set

W

ARNING

LOG PLACEMENT

The positioning of the logs is critical to the safe and clean operation of 
this heater. Sooting and other problems may result if the logs are not 
properly and firmly positioned in the appliance. Never add additional 
logs or embellishments such as pine cones, vermiculite or rock wool 
to the heater. Only use the logs supplied with the unit. 
Failure to position the parts in accordance with diagrams below or to use 
only parts specifically approved for this heater may result in property 
damage or personal injury.

W

ARNING

Before  you  begin 

—  This  unit  is  supplied  with  a  four 

ceramic  fiber  log  units.  Do  not  handle  the  log  unit  with 
your bare hands. 

Always wear gloves to prevent skin 

irritation from ceramic fibers.

 After handling the log unit, 

wash your hands gently with soap and water to remove 
any traces of fibers.

INSTALL EYF24-F LOG UNIT ON BURNER

Figure 18

1.  Install Main Log (#1) on middle and rear supports of 

base. Tabs should fit inside log center opening. Check 
log position and stability.

.  Install  Front  Log  (#)  in  front  of  burner  and  behind 

grate.

3.  Rest rear end Top Left Log (#3) in the indention on the 

main log. Line up hole in bottom of Top Left Log (#3) 
with slot on Front Log.

4.  Position rear end of Top Right Log (#4) on indention of 

main log. Rest front end of Top Right Log (#4) on front 
lot.

LG706
EYF24-F logs

Top Left Log 
#3

Top Right 
Log #4

Main Log 
#1

Front Log 
#

Tabs

Grate Bars

LG706

Figure 18 -
EYF24-F Log Placement

PLACE THE DECORATIVE ROCk 

DO NOT sprinkle volcanic rock on the logs 
or around the pilot or the main burner. This 
may cause sooting. Only place volcanic rock 
on the floor of the fireplace.
During  initial  operation  of  the  new  heater, 
burning logs will give off a paper burning 
smell  and  orange  flames  will  be  present. 
Simply open the windows for a few hours 
to vent the odor.

Summary of Contents for EYF18

Page 1: ...O IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas...

Page 2: ...Remote Receiver 14 Log Placement 15 Flame Appearance 18 Pilot Flame Appearance 18 Burner Flame Appearance 19 Operating Instructions 19 For Your Safety Read Before Lighting 20 Manual Control Lighting I...

Page 3: ...ceramic fiber logs proper location of the heater and annual cleaning are neces sary to avoid potential problems with sooting Sooting resulting from improper installation or operation can settle on su...

Page 4: ...pe of gas indicated on the rating plate This ap pliance is not convertible for use with other gases 20 The heater and its individual shutoff valve must be disconnected from the gas supply piping syste...

Page 5: ...te Max Input Min Input Model Fuel Control BTU h BTU h EYF18NM Nat Manual 30 000 18 000 EYF18PM LP Manual 30 000 22 500 EYF18NV Nat Millivolt 30 000 20 000 EYF18PV LP Millivolt 30 000 24 500 EYF24NM Na...

Page 6: ...r less with openings gasketed or sealed b weather striping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames bet...

Page 7: ...log set in a fireplace that has a restrictive barrier along the bottom front opening of the fireplace Some examples of barri ers are glass screen door frames and sunken recessed fireplaces Height of...

Page 8: ...n To install the gas logs into a fireplace with no wooden mantel shelf or other combustible projection above the fireplace opening measure the heat resistant material height per Figure 5 then see TABL...

Page 9: ...R extend heat resistant material to at least 12 and refer to Figure 8 Less than 8 Extend heat resistant material to at least 8 and install hood CABR CABL refer to Figure 6 OR extend heat resistant mat...

Page 10: ...eat resistant sealant Do not seal the chimney flue damper INSTALLING VENTED APPLICATIONS Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance withANSI...

Page 11: ...e two 2 hooks on front of control panel Make certain front feet of grate are located inside front edge of fireplace or firebox 3 Anchor holes are located on the flange of the unit After centering the...

Page 12: ...the heater s rat ing plate If the gas supply is different DO NOT INSTALL THE HEATER Contact your dealer for the correct model Connecting directly to an unregulated propane LPG tank can cause an explo...

Page 13: ...Switch Millivolt Valve ODS Pilot TH 3 TP 1 TP TH 2 ODS Pilot Spade Terminal Switch Optional Wall Switch or Remote Receiver FP2112 Figure 16 Wiring Diagram Connecting Optional Wall Switch or Thermosta...

Page 14: ...hown in chart by connecting meter test leads to terminals as indicated A Complete Millivolt System Check A Reading Thermostat contacts CLOSED Control knob ON Main burner should turn ON 1 If reading is...

Page 15: ...with soap and water to remove any traces of fibers Install EYF24 F log unit on burner Figure 18 1 Install Main Log 1 on middle and rear supports of base Tabs should fit inside log center opening Chec...

Page 16: ...utouts Figure 22 NOTE Logs 1 2 and 3 have ridges on the bottom which secure the logs to burner frame After installing each log check to be sure it is stable LG707 EYF18 rear log Rear Log 1 LG707 Figur...

Page 17: ...logs to burner frame After installing each log check to be sure it is stable LG712 EYF24 rear log Rear Log 1 LG712 Figure 24 Place Rear Log LG713 EYF24 Middle log MIddle Log 2 LG713 Figure 25 Place Mi...

Page 18: ...gures 29 30 for correct pilot flame If the pilot flame does not touch the thermocouple then the main burner cannot function reliably Refer to Figures 29 30 for incorrect shape of pilot flame Figure 29...

Page 19: ...onents of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial opera...

Page 20: ...ns If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to...

Page 21: ...push and release the piezo ignitor button to light the ODS pilot The pilot is located on the left side of the heater behind the middle log and in front of the back log If piezo ignitor does not light...

Page 22: ...th the control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut ti...

Page 23: ...ent Pages 15 17 for correct log placement Periodic Cleaning Refer to the parts diagram for location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Brush logs wi...

Page 24: ...l shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when installed 5 ODS pilot is clogged 6 Gas regulator setting is no...

Page 25: ...d 1 Burner orifice is clogged or dam aged 2 Burner is damaged 3 Gas regulator is defective 1 Vapors from paint or curing process of logs 1 Turning control knob to HIGH posi tion when burner is cold 2...

Page 26: ...ntrol 1 18D0603 18D0603 18D0603 18D0603 7 Control Valve 1 30D0201 30D0202 30D0201 30D0202 8 Regulator 1 24D0305 24D0306 24D0305 24D0306 Regulator to Valve Tube 1 65D1004 65D1004 65D1004 65D1004 Valve...

Page 27: ...nt Log 1 65D1038K 65D1030K 65D1033K 65D1501K 3 Top Left Log 1 65D0008K 65D1035K 65D1035K 4 Top Right Log 1 65D0009K 65D1034K 65D1034K 5 Rear Log 1 65D1036K 65D1031K 65D1031K 6 Middle Log 1 65D1037K 65...

Page 28: ...65D1009 28 EYF Series Unvented Gas Log Set...

Page 29: ...29 65D1009 EYF Series Unvented Gas Log Set...

Page 30: ...ly with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please r...

Page 31: ...itten warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 MHSC shall not be liable for incidental consequential special...

Page 32: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Reviews: