87D0176
9
B36LA8 & B36RA8 Woodburning Fireplaces
FP2407
B36LR components
B36RA8
Fireplace
B36LA8
Fireplace
RLTSK8
SK84
SK83
SK818
SK81
SKFS2A
OAC4
Combustion Air Assy
403 Duct Connector
RLK Kit
LLK Kit
WB36LR
(Brass)
SKCS8
SK830-2
HI627 Hearth Extension
FP-4-U
Uninsulated Flex Pipe
HI658 Hearth Extension
8-6-12 Flashing
Model Number
Description
B36LA8,
Left or right end open fireplace. Includes wire
B36RA8
firescreen, sealing flue damper and outside
combustion air capability. When installed,
outside combustion air can be connected to
left side. Refer to installation instructions for
details.
SK81
12” chimney section
SK818
18” chimney section
SK83
36” chimney section
SK84
48” chimney section
SK830-2
30° elbows (package contains two 8” diameter
elbows). One pair is required for each offset.
SKCS8
Chimney support. Required when chimney
height exceeds 30’ or 6’ angled chimney run.
RLTSK8
Round top termination.
RLTSK8L
Round top termination - extended.
S20B (R,T,W) Top housing of simulated brick pattern avail-
able in red, tan or white. Appropriate adapter
required. Flashing included. Must include
SLTSK8 or PLTSK8.
SLTSK8
Square chimney cap used to terminate
chimney through a chase. Terra Cotta
masonry. Includes adapter. Flashing
not included.
PLTSK8
Low profile pyramid style chimney cap used to
terminate chimney through a chase. Includes
adapter. Flashing not included.
CF8CA
Adapter kit. Unites square termination with
chimney pipe.
202036
Housing extensions. Extends square
termination on steep pitched roofs.
CT100
Square Chase Termination. Housing used
to terminate chimney through a chase
top. Appropriate adapter required. Flashing
not included.
CTSK
Adapter kit. Unites square termination with
chimney pipe. Required.
8-6-12
0-6/12 pitch flashing for contemporary
installation.
8-12-12
6/12 to 12/12 pitch flashing for contempo-
rary installation.
SKFS2A
Vertical firestop spacer - one required at
each ceiling or floor level.
SKFS6A
30° firestop spacer - for 30° chimney incline
through ceiling or floor.
TWABR
Chimney system adapter collar - converts
fireplace to a 3-wall chimney system.
FP-4-U
4” flexible combustion air duct-8-foot
lengths.
403
4-inch duct connector (for splicing FP-4
ducts). Includes two clamps.
OAC4
4” outside combustion air assembly.
WB36LR
Optional polished brass glass door kit.
H1658
Hearth extension board for front opening
(16” x 58”)
H1627
Hearth extension board for front opening
(16” x 27”)
CCE-SK
Chimney collar enclosure. Provides outside air
to assist in cooling chimney system. (Canada)
AIS-SK
Attic insulation shield. (Canada)
SK818CAN
18” chimney section. (Canada)
SK84CAN
48” chimney section. (Canada)
SK845/2
45° chimney elbows. (package contains 2)
Maximum usage is 2 or 1 pair. (Canada)
Model Number
Description