B36LA8 & B36RA8 Woodburning Fireplaces
FIREPLACE INSTALLATION
&0
MULTISTORYINSTALL
Figure 8
Flue Outlet Height
3’ Min.
Attic Space
Refer to Table 1 for
Roof Opening Sizes
Roof Joist Shields
Firestop Spacer
Installed Above
Joist in Attic
Space
Third Floor Area
“SK8” Series
Chimney
Second Floor Area
First Floor Area
Chimney
Cap
Storm Collar
Flashing
14
Z\x
” Square Hole
in Joist 1
Z\x
” Clear-
ance to Combus-
tibles When Using
Firestop
Max. Installation
Height 86’
14
Z\x
” Square
Hole in Joist
1
Z\x
” Min. Air
Space Clear-
ance Between
Chimney and
combustibles
Firestop Spacer
Firestop
Spacer
FP1883
&0
CHIMNEYLOCATION
Preferred
Location
Poor
Location
FP1882
Figure 9
&0
WALLSHIELDINSTALL
Figure 10
Wall Shield
When Perpen-
dicular Wall is
Less Than 24”
from Opening
48” Clearance from
Perendicular Wall
Models H1658 or
Equivalent Hearth
Extensions
4” Min. when
Wall shield is
Used
16”
23”
16”
36”
Model
WS
Wall
Shield
Models H1627 or
Equivalent Hearth
Extensions
8”
FP2165