28 WG20 Instructions
FL1 Flashing light
Type
Flashing signalling light for automatic gates and doors. The device incorporates a receiving aerial for
remote control
Adopted technology
Visual signalling device with 12V 21W lamp, controlled by MHOUSE automation control units
Lamp
12V 21W BA15 socket (automotive type lamp)
Power supply
The device can be connected only to the "FLASH" and "AERIAL" terminals on the MHOUSE automatic
gate control units
Operating ambient temperature
-20 ÷ 50°C
Not suitable for use in acid, saline or
potentially explosive atmosphere
No
Mounting
Horizontal surface-mounted or vertical wall-mounted
Protection class
IP44
Dimensions / weight
120 x 60 h 170mm / 285g
TX4 transmitters
Type
Radio transmitters for remote control of automatic gates and doors
Adopted technology
AM OOK coded modulation of radio carrier
Frequency
433.92 Mhz
Coding
Rolling code with 64 Bit code (18 billion million combinations)
Buttons
4, each button can be used for the different controls of the same control unit or to control different control
units.
Irradiated power
approx. 0.0001W
Power supply
6V +20% -40% with two CR2016 type lithium batteries
Battery life
3 years, estimated on the basis of 10 commands/day, each lasting 1s at 20°C (at low temperatures the
efficiency of the batteries decreases)
Operating ambient temperature
-20 ÷ 50°C
Not suitable for use in acid, saline or
potentially explosive atmosphere
No
Protection class
IP40 (suitable for use indoors or in protected environments)
Dimensions / weight
72 x 31 h 11mm / 18g
7 Annexes
CE Declaration of Conformity to be filled in and delivered to the owner of the power operated gate.
7.2
Annexe 2: CE Declaration of Conformity of Power Operated Gate
7.3
Annexe 3: Operating Guide
7.1
Annexe 1: CE Declaration of Conformity of WG20 Components
CE Declaration of Conformity of WG20 components; this statement must be attached to the technical documentation.
The following annexes are designed to help you prepare the technical documentation.
Brief guide to be used as an example for drafting the operating guide to be delivered to the owner of the power operated gate.