background image

Input value display

Setting parameter display (CHECK LED ON) 

5

6

CHECK

CHECK

RECORD

RECORD

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

RTC: _HH_

_

___

MM SS

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

L AST: ___________

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

L AST: YYYY- MM- DD_

RC. 3: ___________

RC. 3: YYYY- MM- DD_

RC. 4: ___________

RC. 2: YYYY- MM- DD_

RC. 2: ___________

RC. 4: YYYY- MM- DD_

CHECK

RECORD

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

RESET

TEST

3. Display and button functions

3.2 Display screen descriptions

Trip record display (RECORD LED ON)

Press 

to change 

between % or V

Example

Relay trips using TEST button
Screen display TRIP_PB, respective LED will ON

O/V : 

TRIP%  RELAY

105

AUTO

OV threshold setting (%), Relay Reset

OV Reset level setting (%), Delay time (sec)

O/V :  CLEAR%  DELAY

103

0.100

O/V : 

TRIP%  RELAY

95

AUTO

UV threshold setting (%), Relay Reset

U/V :  CLEAR%  DELAY

97

0.100

OV Reset level setting (%), Delay time (sec)

U/V : 

LO 

LIMIT %

                000

UV non operating zone setting (%)

RTC :  YYYY  MM  DD

09

06

2020

RTC (Real Time Clock) setting

* Available for model wtih RTC 

RTC (Real Time Clock) setting

* Available for model wtih RTC 

* Refer to 3.3 for detail

LAST: 

NO TRIP RECORD

Last trip record memory

LAST:  YYYY  MM  DD 

HH : MM : SS

Latest trip time and date stamping

* Available for model wtih RTC

RC2: 

NO TRIP RECORD

2nd trip record memory

RC2:  YYYY  MM  DD 

HH : MM : SS

2nd trip time and date stamping

* Available for model wtih RTC

RC3: 

NO TRIP RECORD

RC. 2: YYYY- MM- DD_

RC3:  YYYY  MM  DD 

HH : MM : SS

3rd trip record memory

3rd trip time and date stamping

* Available for model wtih RTC 

4th trip record memory

RC4: 

NO TRIP RECORD

RC4:  YYYY  MM  DD 

HH : MM : SS

4th trip time and date stamping

* Available for model wtih RTC

Memory records base on FIFO;
example:
When the relay trip due to OV the record will
be save in LAST and the memory which is in the LAST 
will be push to RC2, same will be as RC3 and RC4.

The record in RC4 will be deleted when new record is being 
push from RC3.

Refer to 3.4 for details

*Will show only if there is trip record

*Will show only if there is trip record

Short press to 

change page, Long press to go

 back main display

Short press to 

change page, Long press to go

 back main display

OUV400

OVER & UNDER VOL

T

AGE RELA

Y

L12     :     380   V

L23     :     380   V

L31     :     380   V

L12, L23 Input value Display

L12     :     100   %

L23     :     100   %

L31     :     380   V

                  TRIP_0V

L31     :     380   V

                  TRIP_PB

RELAY STATUS

PROG

CHECK

FUNCTION

PROGRAM

CHECK

RECORD

TRIP

Over Voltage

RECORD

Under Voltage

RESET

TEST

OUV400

OVER & UNDER VOL

T

AGE RELA

Y

L31 Input value Display

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OUV400

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER

&

UNDER

VOL

T

AGE

RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

OVER & UNDER VOL

T

AGE RELA

Y

L31     :     380   V

                  TRIP_UV

** Refer to setting 'O/V SETTING'
If O/V contact operation setting: OFF
Screen display NO_UV

Trip information display area

Relay trips by OVER VOLTAGE or UNDER VOLTAGE
Screen display TPIP_OV or TRIP_UV, respective LED will ON

L31        :     380   V

NO_OV   |

** Refer to setting 'U/V SETTING'
If U/V contact operation setting: OFF
Screen display NO_UV

L31        :     380   V

NO_UV   |

If O/V and U/V contact operation setting: OFF
Screen display NO_OUV

L31        :     380   V

NO_OUV |

Summary of Contents for OUV-400

Page 1: ...Mun hean singapore Pte Ltd RELAY STATUS PROG CHECK FUNCTION PROGRAM CHECK RECORD TRIP RECORD RESET TEST OPERATION MANUAL OUV400 OVER VOLTAGE UNDER VOLTAGE 01 2021 L12 380 V L23 380 V OVER UNDER VOLTAG...

Page 2: ...Indicators Program Programming mode Check Display of setting Record Display of memory records Type of Fault indicator Over Voltage Under Voltage Trip status indicator Function buttons Test and Reset...

Page 3: ...3 2 Long press to return to the numeric display screen Enter the setting main menu refer to 4 1 Trip test function keys Normal Non trip condition Press once to show PRESS TEST AGAIN TO CONFIRM Press...

Page 4: ...t U V CLEAR DELAY 97 0 100 OV Reset level setting Delay time sec U V LO LIMIT 000 UV non operating zone setting RTC YYYY MM DD 09 06 2020 RTC Real Time Clock setting Available for model wtih RTC RTC R...

Page 5: ...oltage setting Over Voltage threshold setting at 105 Over Voltage contact operation setting AUTO Auto reset CHECK mode ON indication O V CLEAR DELAY O V Over Voltage setting Over Voltage Reset value s...

Page 6: ...Trip memory record display Refer to 3 4 Latest trip record memory Record LED indicates it is in Record memory page Present status Trip LED indicates the relay had trip Overvoltage LED indicates Overv...

Page 7: ...E RELAY OVER UNDER VOLTAGE RELAY OVER UNDER VOLTAGE RELAY OVER UNDER VOLTAGE RELAY Over Voltage Under Voltage OUV400 Over Voltage Under Voltage OUV400 Over Voltage Under Voltage OUV400 Over Voltage Un...

Page 8: ...ncrease speed Value decrease long press to increase speed Confirm setting and return to sub menu U V Setting main menu Range Trip 70 100 Relay OFF AUTO LATCH U V Trip and Relay setting Enter into valu...

Page 9: ...sub menu Enter into value setting digit flashing Value increase long press to increase speed Value decrease long press to increase speed Confirm setting and return to sub menu Over thershold Flashing...

Page 10: ...f full scale Time accuracy 3 of trip time or 20ms Whichever is greater 10 Tripping Relay overvoltage Contact 1c 250Vac 5A undervoltage Contact 1a 250Vac 5A 11 LCD indication 16 x 2 display Real time 3...

Page 11: ...Start Address Lo Number of Word Lo Number of Word Hi Error Check End of Frame 01H FFH 03H 0 nnH 1 nnH CRC Lo CRC Hi 0 nnH 0H 1 Byte 2 Bytes 1 Byte 2 Bytes 2 Bytes Response no error received Start of F...

Page 12: ...x22 0xe2 0xe3 0x23 0xe1 0x21 0x20 0xe0 0xa0 0x60 0x61 0xa1 0x63 0xa3 0xa2 0x62 0x66 0xa6 0xa7 0x67 0xa5 0x65 0x64 0xa4 0x6c 0xac 0xad 0x6d 0xaf 0x6f 0x6e 0xae 0xaa 0x6a 0x6b 0xab 0x69 0xa9 0xa8 0x68 0...

Page 13: ...12 1 31 0 23 0 59 0 59 0 100 1 12 1 31 0 23 0 59 0 59 6 8 Data register Integer format Setting parameter Address Hex Contents Format Word Access Range Unit 0000 0001 0002 0003 0004 0005 0006 0007 000...

Page 14: ...2 L2 L3 4 L3 L1 Multiple phase tripping is possible If reading is 3 2 1 it will indicate that L1 L2 and L2 L3 are having fault 0 Nil 1 L1 L2 2 L2 L3 4 L3 L1 8 Test 0 Nil 1 L1 L2 UV 2 L2 L3 UV 4 L3 L1...

Reviews: