61 / 72
HBC-series V7 LV+MV
NEUTRAL = STOP
MIN = STOP
Start with
programmed
throttle limits
a)
Type of controller’s start
(parameter P5)
is set to „Safety start“ (default value) or „Fast start“
.
In the parameter
P4
„
Control signal
“ is set “
Programmed
“ or some possibility of
Programmed, parameters
II
( under line
====== )
Controller remembers set throttle limits.
1) Turn on control signal source. Joystick
(potentiometer, control voltage, …) is in position
STOP:
=
neutral
for joystick with neutral
=
min. throttle
for joystick without neutral
If not the joystick in the
STOP position, the controller waits for the joystick
(
potentiometer, control voltage
, …)
to move
to this posi-
tion
, before the engine cannot run. The controller indicates the position of the joystick by LED indication:
- signal is
above neutral position
, controller wait for Neutral..…….…….
- signal is
bellow neutral position
, controller wait for Neutral..………….
2) Turn on controller, wait for
blue LED
+
yellow LED
continuous melody …………..
3)
You can start now (controller is ready to run).
b)
Type of controller’s start
(parameter P5)
is set to „
Immediate start
“.
In the parameter
P4
„
Control signal
“is set “
Programmed
“ or some possibility of
Programmed, parameters
II
( under line
====== )
Controller remembers set throttle limits.
1) Turn on control signal source. Joystick
(potentiometer, control voltage, …) is in any position
(any signal value).
The controller does not check joystick
position (if joystick is in the
STOP
position)
after turn-on
!!!
2) Turn on controller, when lights
blue LED
+
other LEDs by current value of driving signal,
! WARNING ! MOTOR START IMMEDIATELY run with PWM (rpm, torque) corresponding with driving signal ! WARNING!
Signal source with Neutral position
Signal source without Neutral position
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
STOP position
100% backward
100% forward
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
STOP position
100% forward
STOP position
♪
♪
♪
čekej
Signal source with Neutral position
Signal source without Neutral position
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
STOP position
100% forward
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
100% backward
100% forward
STOP position