Vega EMS-1 Operating Manual
Page 20
Low Caution:
Enter the pressure value for the low caution. This is the upper value of the lower yellow band.
Low Alarm:
This enables or disables the pressure low alarm.
Low Alarm:
Enter the pressure threshold for when the low alarm must be activated. Any pressure below this value will activate the
alarm.
Data:
Select the data source of the pressure signal. Options include internal (using one of the analog channels within the EMS-
1) or from an optional external RDAC unit.
RDAC Address:
Select the CAN address of the RDAC unit.
4.6.2 Temperature Setup
Mode:
Select the function for the analog channel. Options are “PRESSURE”, “TEMP”, “CURRENT” or “OFF”.
Sender:
Select what type of sender you are using. Select
“VDO 120”
for a VDO 120 degree NTC sender, Select
“VDO 150”
for a
VDO 150 degree NTC sender,
“WESTACH”
for Westach 339 NTC sender,
“MGL”
for a MGL NTC sender,
“LM335”
for a
MGL precision temperature sender or
“USER”
for a custom sender.
If the sender type is set to
“USER"
CALIBRATE SENDER:
If the sender type is set to “
USER”
, then use this menu option to calibrate your pressure sender. See section 4.2.3 for
more information.