10
© MGG Products New Zealand 2021
Setting the warning level & intensity on the collar-receiver
There are 5-settings of warning intensity. Always start with the lowest setting first & monitor your
dog’s response.
•
To turn ON the collar-receiver, PRESS & HOLD the ON/OFF button until the collar beeps
TWICE, then release
•
To set the appropriate level of warning, SHORT-PRESS the button.
Each short-press of the button will gradually increase the warning intensity which is indicated by
the number of light flashes. For example:
1 short-press
= light flashes ONCE for an audible BEEP to warn your dog
2 short-presses = light flashes TWICE for mild intensity static-correction
3 short presses = light flashes 3-TIMES for moderate intensity static-correction
4 short presses = light flashes 4-TIMES for strong intensity static-correction
•
Once set, the warning level will remain the same unless you change it with the short-press of
the button
•
To switch OFF the collar-receiver, PRESS & HOLD the ON/OFF button until the collar-receiver
beeps once
STEP 6:
Setting the boundary-width & testing the collar-receiver
To set the width of boundary zone, determine the total amount of boundary-wire being used. Then
select the appropriate setting with the boundary control switch, located on the side of the
transmitter
(6A).
There are THREE settings:
A
- use this setting for distances of over 750m of boundary-wire
B
- use this setting for up to 400m of boundary-wire
C
- use this setting for distances between 400m
– 750m boundary-wire
Once the boundary-control switch has been set to the correct length of wire used, then set the
width of the static-correction zone using the Boundary-width control knob located on the front of
the transmitter (
6B
).
Set the boundary-width as wide as possible (minimum 2m is recommended) to give your dog a
large enough static-correction zone without further reducing the overall dog containment area.
Note:
The Boundary-width control knob does not alter the intensity of static-correction. This is
covered in STEP 5
– setting the warning level and intensity on the collar-receiver
Setting the static-correction zone
•
Ensure the collar-receiver is prepared and fully charged as per STEP 5
•
Set the collar-receiver to setting 1 (beep only) as described above
•
Attach the collar-receiver test light to the collar-receiver prongs (contact points)
•
Holding the collar-
strap at the level of your dog’s neck, with the prongs pointing upwards
(6E)
,
walk towards the boundary-wire until the collar-receiver beeps and the test light flashes (
6F &