![MGF B/SAFE Use And Maintenance Manual Download Page 4](http://html.mh-extra.com/html/mgf/b-safe/b-safe_use-and-maintenance-manual_1783132004.webp)
4
www.mgfcompressors.it
–
2)
forcing it till blocking. (See the drawing B)Inserire l’altra estremità del tubo con aggancio conico nel
manico dell’aerografo.
3)
Connect the other end of the hose (the one provided with a conical connection) to the spray gun
handle.
4)
Connect the supply plug, respecting the net voltage indicated on the plate
13.
MAINTENANCE (see drawing C)
The two filters must be replaced periodically, or when dirty or clogged. They are placed one in the front area
and one in the back area of the machine. They can be easily extracted from the central hole by using two
fingers. The new filters must be put back by following the same procedure and making them adhere to the
hole inner surface. Their clogging impairs themotor good functioning. If they are not replaced, the motor can
even burn (thus making the warranty expire).
14.
SPARE PARTS
-
Suction filter. Cod. FIL03. (vedi disegno C).
-
3 m air hose, complete with fittings. Cod. ATC03
15.
TECHICAL DATASHEET B/SAFE TMR55
Motor
type
Voltage
Frequen
cy supply
Electric
power
Fan
type
Air
delivered
Pressure
Operating
temp
Dimensions
Weight
Noise
level
double
insulation
230V
50/60Hz
550W
Two-
stage
1800
l/min
64 cfm
0,13 bar
16,4 psi
-10°C
/
+40°C
300x220x310 mm
11,8x8,7x12,2 in
4,8 Kg
10,5 lb
75 dB
double
insulation
115V/
60Hz
550W
Two-
stage
1800
l/min
64 cfm
0,13 bar
16,4 psi
-10°C /
+40°C
300x220x310 mm
11,8x8,7x12,2 in
4,8 Kg
10,5 lb
75 dB
16.
CONSIGLI IN CASO DI MALFUNZIONAMENTO
Problema
Probabile Causa
Rimedio
Turbine does not start
No current
Plug not connected
Check the voltage of the line
The turbine switch, cable or plug
are damaged.
Check the switch, the cable and the plug
Call the Customer Care Technical
Service.
The air flow is too high
and/or low
The air filter is dirty.
Replace the air filter
The air delivery hose is damaged.
Call the Customer Care Technical
Service.
The air delivery hose has not
been tightened in the correct way
Check the air delivery hose tightening.
La turbina emette rumore
Motore danneggiato
Call the Customer Care Technical
Service.
17.
DICHIARAZIONE DI CONFORMITA
The manufacture declres that the B/SAFE TMR55 is produced in conformity with the following
directives/norms:
2002/95/EC RoHS directive
2006/42/EC Machine directive
EN 60204-1:2006 Safety of machines
2004/108/CE EMC directive
EN 61000-3, EN 61000-4, EN 55014-1, EN 55014-2
The manufactures declares that the product has the CE mark