3.

 

PACKAGING/STORAGE  

The machine is packaged in a cardboard box for transport. All optional components (pipes, filters, fittings, 
etc.)  are  placed with  the machine,  in the  same cardboard  box. When  storing  the  machine,  make  sure  the 
surrounding temperature remains included between 

 15

°

 and 40

°

C. Also make sure the humidity values 

in the storage area remain included between 30 and 80%. 
 

4.

 

INSPECTION OF PURCHASED PRODUCT  

Whenreceiving the machine check that: 
- The package is intact and without damages. 
- All the documentation, necessary for the correct installation and use of the machine, is present. 
- The pipe does not present damages or cuts which could compromise its functioning. 

In case of damages inform the reseller. 

Packaging content: 

 

-

 

1 turbine, complete with shoulder belt 

-

 

1 flexible hose of 3 meters 

-

 

1 professional airbrush, complete with plastic airbrush holder to be fixed on the turbine 

-

 

1 instruction manual 
 

5.

 

MACHINE DESCTRIPTION  

Turbine machine for nebulizing, able to supply a great low-pressure air volume (HVLP), characterized by great 
practicality, versatility and simplicity of use. 
 

6.

 

DESCRIPTIVE DRAWING 

1.

 

Power on switch

 

2.

 

Rating label 

 

3.

 

– 

 

4.

 

Motor air filters 

 

5.

 

Air supply tube

 

6.

 

Air supply tube (spray gun) 

 

7.

 

Spray gun/Airbrush

 

8.

 

Supply cable

 

9.

 

Transport handle

 

 

7.

 

TECHNICAL CHARACTERISTICS 

The  blowing  unit  is  fed  by  a  single-phase  electric  voltage  between  220-230/240W  and  50/60Hz.  The  fan 
coupled motor generates an air flow which, canalized into the feed pipe, reaches the spray gun nozzle. The 
high volume at low pressure provides the pulverization of the disinfection product and, wrapped at the same 
time by the air blast, deposits it in a “soft” and precise way on the support which has to be treated. Therefore 
the system allows to prevent or restrict the “fog effect”, thus reducing the dispersal of the sprayed materials 
in  the  air.  The  performance  is  therefore  improved,  and  this  also  helps  the  operator’s  health  and  the 
environment. The machine also produces hot and dry air (by reducing the relative humidity of about 40%), 
thus providing a better and faster drying of the material, especially in case of synthetic enamels. 
All components are of high quality and purpose-made. 
 

8.

 

IDENTIFICATION 

The manufacturer identification and CE conformity plate is placed on the front panel. 

The plate must not be removed for any reason. 

9.

 

 DANGEROUS AND IMPROPER USES  

 

The original configuration of the spraying machine cannot be changed at all. 

Original accessories 

and spare parts always guarantee all safety regulations. 

 

the use of unit in a different way than indicated by the manufacturer could damage the equipment 
and endanger the operator. The unit is not designed to use dangerous, explosive materials and 
herbicides. 

 

Summary of Contents for B/SAFE

Page 1: ...LETTER AND USE OF THE MANUAL This use and maintenance manual is an integral part of the machine and the user must have knowledge of its content Although the main features of the machine described in this manual are not subject to change our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial ...

Page 2: ...pply cable 9 Transport handle 7 TECHNICAL CHARACTERISTICS The blowing unit is fed by a single phase electric voltage between 220 230 240W and 50 60Hz The fan coupled motor generates an air flow which canalized into the feed pipe reaches the spray gun nozzle The high volume at low pressure provides the pulverization of the disinfection product and wrapped at the same time by the air blast deposits ...

Page 3: ...sonnel Net plug In order to perform cleaning or maintenance operations always extract the net plug Avoid accidental starts Never transport the tools connected to the net when your fingers or hands are on the switch Supply extension cable In order to use it outdoors use only type approved extension cables for external use and replace them if they are damaged 11 SAFETY REGULATIONS DURING THE USE The...

Page 4: ...s Weight Noise level double insulation 230V 50 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB double insulation 115V 60Hz 550W Two stage 1800 l min 64 cfm 0 13 bar 16 4 psi 10 C 40 C 300x220x310 mm 11 8x8 7x12 2 in 4 8 Kg 10 5 lb 75 dB 16 CONSIGLI IN CASO DI MALFUNZIONAMENTO Problema Probabile Causa Rimedio Turbine does not st...

Page 5: ...ge our company reserves the right to change those components details and accessories it deems necessary to improve the machine or to meet manufacturing or commercial requirements at any time and without updating this manual immediately ALL RIGHTS ARE RESERVED The reproduction of any part of this manual in any given form without prior written authorization from our company is strictly forbidden 2 C...

Page 6: ...he environment of use The airbrush is used with nebulisable sanitizing disinfectant liquids keep in mind that these can be toxic Provide good lighting of the treated room Do not work indoors without adequate air exchange Chemical considerations DO NOT USE with food or medicines Never point the spray gun in the direction of the human body or on animals Store tools in a safe place Tools not in use m...

Page 7: ...m the treated surface by acting on the adjustment on the lid pos 10 it is possible to adjust the intensity of the nebulization quantity of liquid dispensed and reducing it it is possible to approach the treated surface without the risk of letting the nebulized liquid run off The excessive proximity of the spray gun to the treated surface will cause the liquid to pour out 11 MAINTENANCE To ensure f...

Page 8: ...ed by incorrect use or assembly faults caused by external agents faults caused by negligence or poor maintenance WARRANTY DISCLAIMER The guarantee lapses in the event of arrears or other contractual defaults Repairs carried out under warranty do not interrupt the period of the same The warranty lapses fully if repairs or modifications to our equipment were made without our consent The unit is dism...