TESTING function:
Valve 1
1
open – Valvola 2
2
closed – Valvola 3
3
closed
DISCHARGE after TESTING:
open Valve 2
2
(Valve
1
1
open – Valve
2
2
open – Valve 3
3
closed)
UNCLOGGING function:
Valve 1
1
open – Valve 2
2
closed – Valve 3
3
open
CLEANING function:
Valve 1
1
open – Valve 2
2
closed – Valve 3
3
open
DISCHARGE after UNCLOGGING/CLEANING:
open Valve 2
2
(Valve
1
1
open – Valve
2
2
open – Valve
3
3
open)
USE OF CHEMICAL CLEANING AGENTS
Only neutral chemical solutions are allowed (pH >7)
Please observe the regulations of the manufacture of the chemical as well as the waste water regulations!
SHUTDOWN
Release the dead man’s switch, the spray jet stops.
Switch off the device or deactivate the motor (with reference to article 905550, see the instructions for the internal combustion
engine supplied or contact the S.A.T. Technical Assistance Service - General Information section).
Stop the supply of water (turn off tap).
Venting: Press the dead man’s switch shortly to relieve the pressure.
After using the washing lance: unscrew the washing lance from the high pressure hose and store in the proper lance holder
Emptying the pump: press the dead man’s switch and switch on the motor for about 20 seconds.
Remove the power plug.
Wind the high pressure hose in an orderly fashion onto the reel.
Winter: Store the pump in frost-free places.
Clean the water filter.
9
MGF
MGF
srl –– Via Chico Mendes, 8 – 43058 Sorbolo Mezzani (PR) Italy – Tel. +39 0521-818301 Fax: +39 0521-818202
E-mail:
–