Operating instructions leveller control RS 300 K

 

 
 
 
 
 
 
 
 
 

 

Summary of Contents for RS 300 K

Page 1: ...MFZ Antriebe GmbH Co KG Neue M hle 4 D 48739 Legden EN Operating instructions leveller control RS 300 K...

Page 2: ...ger to property The safety instructions must be observed Information Special information OR Reference to other sources of information 3 General safety instructions Guarantee The function and safety of...

Page 3: ...and bases for testing For connecting programming and servicing the following regulations must be observed the list is not exhaustive Electromagnetic compatibility EN 50014 1 radio disturbance househo...

Page 4: ...Page 4 24 RS 300 K Rev A 05 EN 4 Housing Key Mains switch Button UP Button Autoreturn...

Page 5: ...PE HS1 HS6 connection mains switch X2 terminal block hydraulic unit X3 terminal block command devices X4 terminal block tube motor and signal devices X5 terminal block valves and door X6 socket for i...

Page 6: ...f the dock leveller the hydraulic unit and the com mand and safety devices the relevant manufacturer s instructions are to be adhered to Mains connection Danger To guarantee that the controls function...

Page 7: ...setting 400V 400V 230V Mains supply X1 N L3 L2 L1 PE PE PE 400V 3 PE 230V 3 PE X1 Mains switch L2 L2 S3 S4 S1 S2 L1 L1 S5 S6 L3 L3 X2 Hydraulic unit Note rotating field LED 1 indicates whether a corr...

Page 8: ...door leveller The control of the dock leveller is locked via a potential free contact of the door system or a sensor The polarity of the signal can be adjusted The dock leveller can be operated only...

Page 9: ...manual 1 2 3 4 5 6 X4 N L1 N M 7 8 L1 N Vehicle detector Visual and audible collision safety applied by an approach sensor If a vehicle in front of the gate activates the approach sensor a warning si...

Page 10: ...fence is closed the dock leveller is locked Selector switch Shelter Selector switch for the manual operation of the dock shelter 1 2 3 4 5 6 7 8 9 10 11 12 X3 Free connection 24V Limit switch door lev...

Page 11: ...loating position 7 2 Automatic return AR Upon completion of the loading the dock leveller is returned to its home position by pressing the AR button The AR function expires upon reaching the home posi...

Page 12: ...the mains voltage 230 V 3Phasen should used then the Detection of the phase rotation must be deactivated with the Jumper 1 8 3 Current detection in the folding lip version The RS300 control has an int...

Page 13: ...Display Notice about the running function Notice about the possible errors Operation mode 2 INPUT The values of the different parameters can be changed in the operation mode INPUT Display Notice about...

Page 14: ...turn to INPUT mode and 1 sec INPUT VALVE VER 1 INPUT AR RASIE 1 1 0 INPUT AR DROP 1 5 0 INPUT AR RAISE 2 6 0 INPUT AR DROP 2 2 0 INPUT TIME HYDR 50 INPUT TRAFFIC LIGHT MOD 3 INPUT HORN LIGHT MOD 1 INP...

Page 15: ...u 2 sec Scroll down through menu 2 sec Return to AUTOMATIC mode P Only queries are possible INTERLOCK ON HOME LS OFF ACKOWLEDGE OFF VEHICLE SENSOR OFF LIP FORWARD OFF LIP BACK OFF RAISE OFF HOME OFF D...

Page 16: ...ve 9 4 Operating mode Diagnosis DISPLAY Meaning Status STOP CHAIN Stop circuit Emergency Stop ON circuit closed OFF interrupted fault WHEEL BLOCK Wheel block ON activated OFF not activated INTERLOCK I...

Page 17: ...1 0 1 3 1 AR RAISE 1 Initial time to raise the dock leveller during the AR function from the floating position 0 5 25 Sek 1 Sek AR DROP 1 Time to drop the dock leveler during AR function to ensure th...

Page 18: ...OD 4 MOD 2 MOD 1 MOD 4 MOD2 WHEEL BLOCK MOD1 Wheel block not active MOD2 Wheel block active with actuation during loading procedure the red traffic lights are switched on and the horn signal izes this...

Page 19: ...itched off MOD2 active if the door interlock is interrupted during the loading procedure the leveller remains in floating position both traffic lights switch to red MOD1 MOD2 MOD1 FREE INPUT MOD 1 not...

Page 20: ...LED ON Fuse defectively or phase is missing or to rotary field of the mains supply is wrong Check hydraulic unit cabling and fuses Error message Display Op tion Cause Rectification ERROR HY ZEIT The...

Page 21: ...ains fuses 10A K characteristic Control voltage 24 VDC max 0 9 A Fuse control voltage F4 Resettable fuse 1 6 A Maximal loads Hydraulic unit Max 2 2 KW 6 A Valve 24 VDC 10 0 6 A 100 Mounting Vertical o...

Page 22: ...Page 22 24 RS 300 K Rev A 05 EN...

Page 23: ...RS 300 K Rev A 05 Page 23 24 EN...

Page 24: ...Page 24 24 RS 300 K Rev A 05 EN 1700009826 145841...