9.
Technical
data
Type
(KU
/
KE):
MDF
05-10-15
KU
MDF
05-10-15
KE
MDF
05-14-12
KU
MDF
05-14-12
KE
MDF
20-22-12
KU
MDF
20-22-12
KE
MDF
20-15-17
KU
MDF
20-15-17
KE
MDF
20-15-12
KU
100%
MDF
20-15-12
KE
100%
MDF
20-10-17
KU
100%
MDF
20-10-17
KE
100%
Driving
torque
(Nm):
100
/
140
220
/
150
150
/
100
Maximum
safety
catch
torque
692
1188
1188
(Nm):
Permissible
torque
(Nm):
151
259
259
Driving
motor
speed
(min
-1):
15
/
12
12
/
17
12
/
17
Motor
output
(kw):
0.37
0.75
0.55
Operating
voltage
(V):
400
/
3~
400
/
3~
400
/
3~
Mains
frequency
Hz:
50
50
50
Control
voltage:
(V):
24
24
24
Nominal
motor
current
(A):
2.1
2.8
/
2.6
1,8
/
1.7
Motor
duty
cycle
(%):
60
60
100
Cable
on
site
(mm
2
):
5
x
1.5
5
x
1.5
5
x
1.5
Fuse
protection
on
site
(A):
10.0
10.0
10.0
Protection
type
(IP)
54
54
54
Temperature
range
(°C):
-20
/
+60
-20
/
+60
-20
/
+60
Continuous
sound
pressure
level
<
70
<
70
<
70
(dB
(A)):
Weight
per
piece
(kg):
22
/
25
20
/
23
/
20
/
23
22
Maximum
number
of
13
18
18
revolutions
of
driven
shaft:
Hollow
shaft
(mm):
30
30
30
16
–
Roll-Up
Door
Operator
/
MDF
/
Rev.
0.0
Summary of Contents for MDF 05-10-15
Page 1: ...Operating Instructions for Roll Up Door Operators MDF GB Roll Up Door Operator MDF Rev 0 0 1...
Page 21: ...GB MDF 20 22 12 KE Chain MDF 20 15 17 KE Chain Roll Up Door Operator MDF Rev 0 0 21...
Page 23: ...GB MDF 30 42 12 KU Crank MDF 30 42 12 KE Chain Roll Up Door Operator MDF Rev 0 0 23...
Page 25: ...GB MDF 30 27 12 KU 100 Crank MDF 30 30 12 KU Crank Roll Up Door Operator MDF Rev 0 0 25...
Page 27: ...GB MDF 30 50 12 KE Chain MDF 50 65 10 KU Crank Roll Up Door Operator MDF Rev 0 0 27...
Page 29: ...GB MDF 50 75 10 KE Chain MDF 6 100 9 KU Crank Roll Up Door Operator MDF Rev 0 0 29...
Page 32: ......