background image

4

General Information

Introduction

We extend a warm welcome from all of us at Masonry 

Fireplace Industries, LLC. (MFI), proud manufacturers of  

Mason-Lite Fireplaces.

Thank you for Choosing MFI.

You may have thought long and hard before you chose the 

fireplace which would grace your home. Rest assured that 

every component of the Fireplace has been tested to ensure 

long-term durability.

Before Beginning the Installation

Read these instructions carefully before beginning the 

installation of this Vent-Free fireplace. Also read the gas 

log appliance manufacturer’s literature regarding sizing 

and suitability for installation into this Enclosure prior to 

installation.

Statement of Intended Use:

The Mason-Lite Vent-Free Universal Masonry Fireplace is a 

modular refractory masonry unit designed for field assembly. 

The firebox is constructed using pre-cast, interlocking 

refractory blocks. The blocks are then secured to each other 

using Mortar. The system includes all parts necessary for the 

assembly of a complete masonry vent-free decorative gas log 

enclosure. 

In addition to the basic enclosure, a standard 1-1/8” thick, 

high temperature refractory brick is required to line the interior 

of the firebox.

These fireplaces are not intended to serve as a primary 

heat source, rather, the fireplace was expressly created as a 

supplemental source of heat.

The MASON-LITE is Designed for Use Only with any Vent 

free decorative gas log sets meeting standard ANSI Z21.11.2

Vent free decorative gas log sets meeting standard ANSI 

Z21.11.2, are supplied by others and are limited to any listed 

vent-free gas-fired log sets with heat input ratings up to 

40,000 Btu/hr.

WARNING:

 Any application other than the “Intended Use” as 

stated above is in violation of the manufacturer’s instructions 

and is hereby prohibited. Such violation may cause immediate 

hazard, property damage or loss of life and will void all 

liabilities to the manufacturer and will void all warranties 

explicit or implied.

Product Overview

Mason-Lite fireplaces are designed as Factory Built - Field 

Assembled Fireplaces to be installed on both combustible and 

non-combustible floor systems. They have been extensively 

tested to perform with excellent results in this environment.

Attention: Be advised that all the illustrations in this manual 

are for general reference only. They are not drawn to scale. 

Actual design elements will vary from case to case. Pay 

attention to specified minimum clearances as they relate to 

combustible materials.

 *32" 

A

A

 *38" 

 *45 3/4" 

 4 1/2" 

 43" 

 39" 

 28 1/2" 

 28" 

 23" 

SECTION A-A

Figure 2

ALL DIMENSIONS ARE IN INCHES.

* VERTICAL DIMS. ARE DRY STACK MIN., MORTAR 

THICKNESS MAY ADD A TOTAL OF 1 INCH TO 

OVERALL HEIGHT.

MODEL

MFP39VF

MFP44VF

MFP49VF

W1

43”

48”

53”

W2

39”

44”

49”

W3

29-1/4”

34-1/4”

39-1/4”

Summary of Contents for MASON-LITE MFP39VF

Page 1: ...rebox has been tested and approved by PFS under ANSI Z21 91 for use with any ANSI Z21 11 2 approved gas logs IMPORTANT READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OF THIS FIREPLACE...

Page 2: ...tallation Information Pg 12 Fireplace Assembly Procedures Pg 13 15 Gas Piping Installation Pg 15 Electrical Line Feed Pg 15 Firebrick Liner Installation Pg 16 Initial Fireplace Operation Pg 16 Appendi...

Page 3: ...d with this appliance may result in property damage or personal injury Customer Service Parts Replacement Parts and accessories may be purchased from your local dealer Additional information is availa...

Page 4: ...WALL 8 5 MFP39 5 MFP44 5 MFP49 5 DOME REAR LOWER 1 6 MFP39 6 MFP44 6 MFP49 6 LINTEL 1 6A MFP39 6A MFP44 6A MFP49 6A LINTEL FRONT 1 6B MFP39 6B MFP44 6B MFP49 6B T BAR 1 7 MFP39 7 MFP44 7 MFP49 7 DOME...

Page 5: ...he fireplace was expressly created as a supplemental source of heat The MASON LITE is Designed for Use Only with any Vent free decorative gas log sets meeting standard ANSI Z21 11 2 Vent free decorati...

Page 6: ...pilot light safety system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation page 10 If the fireplace keeps shutting off see appliance manufac...

Page 7: ...Attention You may need a building permit to install a MASON LITE fireplace Check with the local jurisdiction before you get started W H D Figure 4 Height may vary Maintain 1 2 inch clearance to top of...

Page 8: ...strated in Figures 6 and 7 Figure 10 illustrates the general arrangement of anchorage to floor framing It is important to take into consideration that the load for the Mason Lite Fireplace must be con...

Page 9: ...structural members having a moisture content of less than 16 per cent at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be substituted for the...

Page 10: ...tion However all such trim material must meet standard fireplace code requirements Non combustible facing material must be applied to a minimum of eight inches 8 beyond the sides of the finished openi...

Page 11: ...of vented fuel burning appliances Non combustible Flex Hose Figure 16 Exterior Providing Adequate Ventilation In accordance with the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Com...

Page 12: ...r Gas fireplace logs ________ Btu hr Other gas appliances ________ Btu hr Total ________ Btu hr Example Gas water heater 40 000 Btu hr Vent free fireplace 36 000 Btu hr Total 76 000 Btu hr Do not incl...

Page 13: ...will have grout applied prior to assembly This will minimize shrinkage and cracks developing in the joint areas Best way to accomplish this is with a bucket of water and a large sponge Dip sponge int...

Page 14: ...rface flatness level if necessary 4 Apply mortar to the remaining Hearth except this time apply beading on surface to be facing floor as shown in Figure 19 Figure 19 Hearth shown prepared for Left Sid...

Page 15: ...nstall Lintel 10 Install Lower Rear Dome flush to the rear walls as shown in Figure 23 Figure 23 Lintel Lower Rear Dome T Bar Lintel Front 11 Place Lower Side Domes between Lintel and Lower Rear Dome...

Page 16: ...Gas Code ANSI Z223 1 This gas pipe provision must only be connected to an approved vent free gas log heater certified to ANSI Z21 11 2 heater standard Check local building codes for specific pipe and...

Page 17: ...the outside combustion air kit is to be installed The following Firebrick Patterns are available from MFI MFP XX SHBL Herring Bone Figure 30 MFP XX FRBL Running Bond Figure 31 Initial Fireplace Operat...

Page 18: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Page 19: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Page 20: ...his warranty makes MFI or any affiliate thereof liable in any respect for any injury or damage to the building or structure in which the fireplace has been installed or to the persons or property ther...