Raised and Flush Hearth Application:

If you would prefer to have a raised hearth, the Vent-Free 

box can be raised to the desired height using wood studs or 

concrete blocks.

Figure 26

Concrete Block 

Raised Platform

 

When determining raised hearth height, be sure to 

allow  for  the  3”  thick  firebox  hearth  and  1-1/2”  thick  firebrick 

floor, in addition to the height of base platform.

Figure 27

Raised Wood 

Platform

 

For a “flush hearth” (fireplace floor flush with the room’s 

floor) the base plate can be omitted from the assembly and the 

firebox  walls  built  directly  on  the  concrete  support  slab.  The 

fire brick floor of the firebox is then set directly to the concrete 

support slab. This makes the fireplace finished fire brick floor 

approximately one and one-half inches (1-1/2”) above the top 

of the concrete support slab. 

Gas Piping Installation

 

The provision for installation of a gas pipe is only for 

connection to a Vent free decorative gas log sets meeting 

standard ANSI Z21.11.2

 

Familiarize  yourself  with  requirements  for  installation  as 

outlined by the National Fuel Gas Code, ANSI Z223.1.

 

This gas pipe provision must only be connected to an 

approved  vent-free  gas  log  heater  certified  to ANSI  Z21.11.2 

heater  standard.  Check  local  building  codes  for  specific  pipe 

and material requirements.

1)  Gas piping can be routed from the floor, rear or side walls. 

With a masonry drill, follow the instructions from the gas 

appliance manufacturer. Any wires must be routed through 

separate  conduit.  Make  sure  provisions  are  made  for 

access to manual shut-off valve.

Figure 28

CSA  Certified  Manual 

Shut-off Valve

Tee-joint

Sediment 

Trap

Approved 

Flexible 

Gas Line

3” 

Minimum

Pipe 

Nipple

Cap

From External

 Regulator 

(11-14” W.C. pressure)

2)  After routing piping, fill hole around pipe with MASON-LITE 

mortar.

Electrical Line Feed

  Electrical line feed can be routed through the Standard 

firebox  back wall, side walls or floor by drilling an appropriately 

sized hole using a masonry drill bit. Be sure to follow the 

Vent free decorative gas log Manufacturer’s explicit electrical 

line  connection  instructions  for  vented  masonry  fireplace 

installations.

NOTE: Gas line and electric line must be routed through 

separate access holes.

Firebrick 

Side

Gas or

Electric Line

Figure 29

IMPORTANT

All access holes must be grouted with mortar to 

seal any gaps or cracks.

Summary of Contents for MASON-LITE MFP39VF

Page 1: ...rebox has been tested and approved by PFS under ANSI Z21 91 for use with any ANSI Z21 11 2 approved gas logs IMPORTANT READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OF THIS FIREPLACE...

Page 2: ...tallation Information Pg 12 Fireplace Assembly Procedures Pg 13 15 Gas Piping Installation Pg 15 Electrical Line Feed Pg 15 Firebrick Liner Installation Pg 16 Initial Fireplace Operation Pg 16 Appendi...

Page 3: ...d with this appliance may result in property damage or personal injury Customer Service Parts Replacement Parts and accessories may be purchased from your local dealer Additional information is availa...

Page 4: ...WALL 8 5 MFP39 5 MFP44 5 MFP49 5 DOME REAR LOWER 1 6 MFP39 6 MFP44 6 MFP49 6 LINTEL 1 6A MFP39 6A MFP44 6A MFP49 6A LINTEL FRONT 1 6B MFP39 6B MFP44 6B MFP49 6B T BAR 1 7 MFP39 7 MFP44 7 MFP49 7 DOME...

Page 5: ...he fireplace was expressly created as a supplemental source of heat The MASON LITE is Designed for Use Only with any Vent free decorative gas log sets meeting standard ANSI Z21 11 2 Vent free decorati...

Page 6: ...pilot light safety system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation page 10 If the fireplace keeps shutting off see appliance manufac...

Page 7: ...Attention You may need a building permit to install a MASON LITE fireplace Check with the local jurisdiction before you get started W H D Figure 4 Height may vary Maintain 1 2 inch clearance to top of...

Page 8: ...strated in Figures 6 and 7 Figure 10 illustrates the general arrangement of anchorage to floor framing It is important to take into consideration that the load for the Mason Lite Fireplace must be con...

Page 9: ...structural members having a moisture content of less than 16 per cent at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be substituted for the...

Page 10: ...tion However all such trim material must meet standard fireplace code requirements Non combustible facing material must be applied to a minimum of eight inches 8 beyond the sides of the finished openi...

Page 11: ...of vented fuel burning appliances Non combustible Flex Hose Figure 16 Exterior Providing Adequate Ventilation In accordance with the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Com...

Page 12: ...r Gas fireplace logs ________ Btu hr Other gas appliances ________ Btu hr Total ________ Btu hr Example Gas water heater 40 000 Btu hr Vent free fireplace 36 000 Btu hr Total 76 000 Btu hr Do not incl...

Page 13: ...will have grout applied prior to assembly This will minimize shrinkage and cracks developing in the joint areas Best way to accomplish this is with a bucket of water and a large sponge Dip sponge int...

Page 14: ...rface flatness level if necessary 4 Apply mortar to the remaining Hearth except this time apply beading on surface to be facing floor as shown in Figure 19 Figure 19 Hearth shown prepared for Left Sid...

Page 15: ...nstall Lintel 10 Install Lower Rear Dome flush to the rear walls as shown in Figure 23 Figure 23 Lintel Lower Rear Dome T Bar Lintel Front 11 Place Lower Side Domes between Lintel and Lower Rear Dome...

Page 16: ...Gas Code ANSI Z223 1 This gas pipe provision must only be connected to an approved vent free gas log heater certified to ANSI Z21 11 2 heater standard Check local building codes for specific pipe and...

Page 17: ...the outside combustion air kit is to be installed The following Firebrick Patterns are available from MFI MFP XX SHBL Herring Bone Figure 30 MFP XX FRBL Running Bond Figure 31 Initial Fireplace Operat...

Page 18: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Page 19: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Page 20: ...his warranty makes MFI or any affiliate thereof liable in any respect for any injury or damage to the building or structure in which the fireplace has been installed or to the persons or property ther...

Reviews: