mFi MASON-LITE MFP- 75 Instructions Manual Download Page 5

 

 

 

Summary of Contents for MASON-LITE MFP- 75

Page 1: ...Rev 06 2017 Masonry Firebox Model MFP 75...

Page 2: ...e Floor Installation Pg 11 What You Will Need Pg 12 MFP 75 Fireplace Assembly Pg 13 15 Installing Damper and Chimney System Pg 16 Firestop Radiation Shield Pg 17 Fireplace Finishes and Combustible Tri...

Page 3: ...2 MFP 75 Fireplace Parts Diagram Parts List...

Page 4: ...3 Fireplace Overall Dimensions...

Page 5: ...4...

Page 6: ...5...

Page 7: ...6...

Page 8: ...EPLACE ATTENTION A fire or an explosion could occur causing property damage injury or loss of life if you do not follow the information in this manual NOTE THIS MANUAL MUST BE REPRODUCED ONLY IN ITS E...

Page 9: ...lates to combustible materials Familiarity of installation for all components The strength of the floor on which it rests Chimney system measurements Choice of materials and craftsmanship in fireplace...

Page 10: ...It is the responsibility of the contractor installer not the manufacturer to ensure that adequate combustion air is provided for proper function of this fireplace Fireplaces take up a large volume of...

Page 11: ...box the addition of floor joists to align with the anchor brackets allows the brackets to be directly connected to the floor joists Note that additional floor joists may be required to support the wei...

Page 12: ...allation in order to take up any slack in the threads Hearth Ember Shields Metal safety stripping is required between the front of the Fireplace Hearth and Hearth Extension not supplied A 26 gauge gal...

Page 13: ...Ten 10 pieces 3 8 rebar x 36 long included with unit Ten 10 ea All thread x 12 long with nuts and washers Metal base 8 inch 1 ceramic fiber blanket the size of the hearth base to go under the metal ba...

Page 14: ...tween slabs for the additional mortar to unite the remaining slabs Continue process for remaining hearth sections while moistening and adding mortar between joints at slab ends 4 Apply mortar in like...

Page 15: ...e Lintel and Lower Rear Dome in place as shown Each will be in two halves There will be a 90 degree angle iron placed behind the lintel for support Angle iron is not included Check that all is level I...

Page 16: ...ustments to the fireplace alignment before continuing to the next step 17 Assemble Upper Domes which also come in one longer piece and one shorter piece and Dome Sides as shown Check your assembly her...

Page 17: ...e finished fireplace these clearances must be followed when building the framework for the chimney system Note that the most important aspect of the installation is maintaining the minimum required cl...

Page 18: ...homes that are very well insulated and tightly sealed Check local building codes for specific requirements Install Combustion Air Kit MFP4 AK into the MASONLITE Firebox through the side wall opening p...

Page 19: ...icularly pine WARNING Burning of above mentioned materials will cause an unsafe condition and will void your warranty Starting a Fire and Basic Operation Before starting a fire in your fireplace open...

Page 20: ...ues of slow burning fires hence creosote residue collects on the flue lining Because of soot and creosote build up it is recommended that the fireplace and chimney cleaning be done twice a year In col...

Page 21: ...20...

Page 22: ...FI or any affiliate thereof liable in any respect for any injury or damage to the building or structure in which the fireplace has been installed or to the persons or property therein arising out of t...