mFi Mason-Lite LMFP-108 Instructions Manual Download Page 37

37

Lifetime  Limited Warranty

Mason-Lite Appliances

Masonry Fireplace Industries, Inc. warrants all Mason-Lite Appliances to be free from defects in materials that adversely affect appliance 

performance for the lifetime of the product from the date of purchase, subject to the terms and conditions of this limited warranty. Masonry 

Fireplace Industries does not warrant accessory chimney, outside air ducts and devices not manufactured by Masonry Fireplace Industries.

This warranty covers only products manufactured by Masonry Fireplace Industries, specifically the modular concrete firebox, and 

NO 

WARRANTY, EXPRESS OR IMPLIED, EXTENDS TO ANY OF THE HARDWARE, FOUNDATION, VENTING, DUCTS, OR 

ACCESSORIES. THIS WARRANTY DOES NOT COVER DRAFTING, SMOKING, OR SOOTING OF THE APPLIANCE 

SYSTEM

.  Factors beyond the manufacturer’s control affect drafting, smoking, and sooting and Masonry Fireplace Industries cannot guarantee 

these aspects of performance.

Coverage under this warranty is subject to the following conditions and exclusions:

• 

This warranty is null and void when the appliances are not installed pursuant to the installation instructions provided by Masonry 

Fireplace Industries or local building codes have not been followed completely.

• 

This warranty does not apply to any component or part that shows evidence of misuse, abuse, improper installation, accident or lack of 

regular maintenance.  Masonry Fireplace Industries is not responsible for misuse or mishandling of component parts.

• 

This warranty does not apply to any damage sustained to the appliance while in transit.

• 

Neither Masonry Fireplace Industries, nor any affiliate thereof, is responsible for any labor costs or indirect costs incurred for the 

replacement of defective components.  Any covered component that, in our judgment, is defective shall be repaired, replaced or refunded 

at Masonry Fireplace Industrie’s option.

• 

Nothing in this warranty makes Masonry Fireplace Industries, or any affiliate thereof, liable in any respect for any injury or damage to 

the building or structure in which the appliance has been installed or to the persons or property therein arising out of the use, misuse, or 

installation of properly manufactured Masonry Fireplace Industries products.

• 

The appliance must be used in accordance with operating instructions. Only approved Burners and Glass Doors must be installed when 

using the appliance. 

NEITHER MASONRY FIREPLACE INDUSTRIES, NOR ANY AFFILIATE THEREOF, SHALL BE HELD LIABLE FOR ANY 

INCIDENTAL OR CONSEQUENTIAL DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE APPLIANCE. ALL 

SUCH DAMAGES AND EXPENSES ARE HEREBY EXCLUDED. Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the above limitation or exclusion may not apply to you.

If a component is found to be defective under the terms of this warranty, the party this warranty is extended to shall notify Masonry Fireplace 

Industries, 

6391 Jurupa Ave., Riverside, California 92514

 in writing, by registered mail, within thirty (30) days following the discovery 

of the defect within the lifetime warranty period. The letter shall include proof of purchase and state the (1) date of purchase, model number 

and serial number ; (2) place of purchase; (3) address of installation; (4) name, address and phone number of the homeowner; and (5) a brief 

description of the defect.

This warranty applies only to those appliances installed in the continental United States, Alaska and Canada. If any part of this warranty is 

found to be unenforceable, the remaining parts shall remain in force and effect.

Electronic valves and modules are limited to only one year warranty under the valve and electronic parts manufacturers warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, TERMS OR CONDITIONS, 

EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW.  MASONRY FIREPLACE INDUSTRIES HEREBY 

DISCLAIMS ALL GUARANTEES AND WARRANTIES, EXPRESS OR IMPLIED, BEYOND THE WARRANTIES SET FORTH HEREIN, 

INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some 

states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

Revision date: 5/4/2019

Masonry Fireplace Industries Inc.

6391 Jurupa Ave., Riverside, California 92514

Telephone (800) 345-7078  Fax (951) 588-8046

Summary of Contents for Mason-Lite LMFP-108

Page 1: ...I Z21 50 standard Solid fuels shall not be burned in this appliance This appliance must be vented vertically through the roof This appliance is not for installation in manufactured or mobile homes The...

Page 2: ...Pg 20 Mason Lite Firebrick Liners Pg 21 Appliance Finishes and Combustible Trim Clearances Pg 21 Installing Outside Air Pg 21 Mason Lite Chimney Systems Pg 22 23 Venting Installation Pg 24 Chimney Ter...

Page 3: ...uctions Note Certain installation conditions may require an Enervex Exhausto Termination System including ADC100 Controller Consult Manual Chimney Heights Horizontal vent runs are approved for up to 7...

Page 4: ...4 LMFP 48 60 72 84 Appliance Parts Diagram LMFP 48 60 72 84 Appliance Parts Diagram Figure 2 14 19 18 16 15 12 13 7 8 6 5 2 3 1 4 9 10 17 20 11 IT...

Page 5: ...T HOLE 1 4 SIDE WALL 5 5 REAR WALL SML SEC 3 6 REAR WALL 3 7 5 x 3 x 61 x 25 ANGLE IRON NOT SUPPLIED SOURCE LOCALLY 1 8 LOWER DOME FRONT 2 9 LINTEL 2 10 SMOKE SHELF 1 11 SPILL SWITCH 1 12 LOWER SIDE D...

Page 6: ...17 16 17 8 9 17 18 8 9 11 13 14 12 13 11 15 20 21 5 6 4 3 7 5 5 1 2 2 1 5 7 6 6 10 23 24 5 4 22 Figure 1 WARNING Failure to position the parts in accordance with these diagrams or failure to use only...

Page 7: ...ER DOME FRONT CENTER 1 13 LINTEL 2 14 LINTEL CENTER 1 15 4X3 ANGLE IRON NOT SUPPLIED SOURCE LOCALLY 1 16 UPPER DOME SIDE 2 17 UPPER DOME 4 18 UPPER DOME CENTER 2 19 DOME TOP 2 20 SPILL SWITCH CHANNEL...

Page 8: ...stand each phase completely before going on to subsequent instructions Attention All the illustrations in this manual are for general reference only Do not scale drawings Actual design elements will v...

Page 9: ...xamples of multiple configurations Please consult with local Structural Engineer for suspension and support calculations 4 Sided option Left Side option Peninsula option Right Side option See Thru opt...

Page 10: ...e The burner specified for use with this gas appliance is non convertible and only meant to be used with the gas listed on the rating plate GUIDELINES FOR USE All current and future users of Mason Lit...

Page 11: ...RAMING NON COMBUS H2 SPILL SWITCH CHANNEL Appliance Framing Dimensions Non Combustible Floor Systems Figure 6 WARNING Failure to position the parts in accordance with these diagrams or failure to use...

Page 12: ...k Lining Attention Any gaps between the appliance front and fascia material should be sealed with non combustible epoxy PLAN 2 2 2 8 MIN 2 MIN MIN PLAN MIN MIN 113 2 MIN 8 NON COMBUSTIBLE FACING MATER...

Page 13: ...ance Overall Dimensions LMFP 120 Figure 8a LMFP 120 Appliance Overall Dimensions ALL DIMENSIONS ARE IN INCHES ALL DIMENSIONS ARE MINIMUM MORTAR THICKNESS MAY ADD A TOTAL OF UP TO 1 INCH TO THE OVERALL...

Page 14: ...remain hot for a time afterward Allow the surface to cool before touching it Carefully supervise young children when they are in the room with the appliance All appliance openings for both combustion...

Page 15: ...e addition of floor joists to align with the anchor brackets allows the brackets to be directly connected to the floor joists Note that additional floor joists may be required to support the weight of...

Page 16: ...I 240 1 For wood structural members having a moisture content of less than 16 per cent at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be sub...

Page 17: ...bar x 36 long included with unit Eight 8 ea All thread x 12 long with nuts and washers ALL UNITS Three 3 90 lb bags of ready mix concrete with 1 4 or smaller aggregate 6 Structural Metal Base to allow...

Page 18: ...h dimension allows for an approximate gap of 1 8 between slabs for the additional mortar to unite the remaining slabs Continue process for remaining hearth sections while moistening and adding mortar...

Page 19: ...he last tier of side walls are installed place 3 rebar 3 ft long pieces vertically through the cells into the holes in the hearth adjacent to the rebar and or all thread sticking up from the hearth an...

Page 20: ...s are smooth and uniform Make sure connections are covered with an adequate amount of mortar Remember that you have the option of using shims but they must be removed and any holes filled Make any adj...

Page 21: ...E SHEATHING ZONE 2 2 2 NON COMBUSTIBLE ONLY ZONE Figure 30 Mantel clearances 2 Walls That Adjoin Safety codes and all practical outlooks insist that your appliance cannot be installed closer than 2 ft...

Page 22: ...fts caused by faulty mechanical systems adverse weather conditions or any other inclement environmental situations over which the manufacturer has no control 5 Inspect all appliance chimney components...

Page 23: ...l be required for the installation Bear in mind that the minimum height of the Mason Lite once installed is 14 0 fourteen feet and that it is higher if offsets are used Here is how to calculate the he...

Page 24: ...only through the outer chimney For systems needing multiple offsets with sections over 4 four feet please use an Enervex Fan to ensure a good positive draft Venting Installation Venting Installation...

Page 25: ...be painted in order to protect it them from rusting and weathering Particularly if you are installing the appliance and chimney near water or in a high humidity area the manufacturer recommends a top...

Page 26: ...ay be necessary Nominal BTU based on gas inlet pressure Nominal gas inlet pressure for natural gas is 5 W C Installing the valve control box assembly 1 Fasten the valve control box assembly to a stud...

Page 27: ...l be able to run the burner for as long as you like Attaching the Burner and the Grate 1 Unpack the burner assembly and place the rear legs of the burner into the brackets in the back of the firebox 2...

Page 28: ...as far forward as possible while keeping the back parallel with the burner pipe Figure 41 3 Place top logs across the front and back logs in the order and positions shown in Figure 44 WARNING Failure...

Page 29: ...URES DRAWN MODEL CHECK QA THIS DOCUMENT AUTHENTICATED WITH DIGITAL SIGNATURES MENT CONTAINS CONFIDENTIAL INFORMATION AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT WRITTEN AUTHORIZATION FROM...

Page 30: ...30 LOG SET 120 Figure 49...

Page 31: ...ease and all flames main burner and pilot will go out see important note below OPERATING THE BURNER USING THE REMOTE Move the wall switch to the REMOTE position and follow the instructions included in...

Page 32: ...valve is installed on either the gas in or gas out side of the valve It is recommended to hard pipe in the connec ons with unions installed inside the box PILOT INSTALLATION Un coil the pilot tubing t...

Page 33: ...it is impera ve that you follow the steps outlined below to ensure proper and safe opera on If you encounter any irregulari es refer to the TROUBLESHOOTING GUIDE 1 Check all wiring connec ons 2 Turn o...

Page 34: ...Pilot generator may not be producing sufficient millivolts a Check with a millivolt meter Should be 250 millivolts or more b Pilot flame making a blowing sound b Pilot needs adjusting see Checking an...

Page 35: ...slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MINIMUM...

Page 36: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Page 37: ...been installed or to the persons or property therein arising out of the use misuse or installation of properly manufactured Masonry Fireplace Industries products The appliance must be used in accordan...

Reviews: