Your reduced clearance kit is comprised of two parts, depending on your model: 

Nova Reduced Clearance Kit 

(MF02-RCK) 

Nova 2/Nova 2 Tower Reduced Clearance Kit 

(MF03-RCK) 

Nova Series Pipe Shield (0364-000-C) 

Nova Series Pipe Shield (0364-000-C) 

Nova Reduced Clearance Air Duct (N92) 

Nova 2 Reduced Clearance Air Duct (N93) 

 
The pipe shield should be placed atop the stove, centered behind the double wall connector 

pipe. It must be set back by ½” off the back of the double wall pipe. No additional securement is 

needed. 

If the pipe shield is

 

damaged or removed, the stove cannot be operated unless 

clearance to combustibles are re-evaluated based on guidance in the respective product 

Owner’s Manual. Failure to follow all clearance to combustible requirements may result 

in property damage, damage, bodily injury, or even death.

 

 
The reduce clearance air duct should be hung from the two rear air duct bolts already installed 

on the rear of the stove.  

 